Intraocular pressure increase after Nd:YAG laser capsulotomy and anterior segment optical coherence tomography analysis

被引:1
作者
Keles, Ali [1 ]
Karaman, Suleyman Korhan [2 ]
机构
[1] Bilecik Seyh Edebali Univ, Fac Engn, Dept Ophthalmol, TR-11230 Bilecik, Turkiye
[2] Univ Hlth Sci, Ulucanlar Eye Training & Res Hosp, Dept Ophthalmol, Ankara, Turkiye
关键词
Anterior chamber angle; Anterior segment optical coherence tomography; Intraocular pressure; Nd:YAG laser capsulotomy; POSTERIOR CAPSULOTOMY; CHAMBER DEPTH; NEODYMIUM; REPRODUCIBILITY; REFRACTION; ELEVATION;
D O I
10.1007/s10103-023-03958-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study is to determine whether post-procedure intraocular pressure (IOP) increase is associated with the anterior chamber angle in cases of Neodymium: yttrium-aluminum garnet (Nd: YAG) laser capsulotomy. The study included 51 eyes with posterior capsule opacification. Initial IOP values of the patients were compared with IOP values without intraocular pressure-lowering administration at the end of the 1st hour, 1st day, 3rd day, and 7th day after Nd:YAG laser capsulotomy. The anterior segment angle configuration was evaluated using anterior segment optical coherence tomography analysis without dilatation before the procedure. The anterior chamber angle (ACA) and angle opening distances of 500 and 750 mu m (AOD500 and AOD750) in the nasal and temporal quadrants were examined. The mean pre-laser IOP value only increased significantly at 1st hour post-laser (13.02 +/- 3.02 mmHg vs 14.16 +/- 4.07 mmHg, p = 0.016). In eyes with ACA below 40 degrees in both the nasal and temporal quadrants, mean IOP increased significantly at 1st hour post-laser (p = 0.025 and p = 0.032, respectively), while it was not significant in eyes with ACA above 40 degrees (p > 0.05). No correlation was found between ACA, AOD500, and AOD750 values and IOP changes at the first hour (p > 0.05). Except for the first hour after Nd:YAG laser capsulotomy, no significant increase in IOP was observed. This elevation was higher in eyes with ACA less than 40 degrees. In patients with a narrow ACA, first-hour follow-up may be beneficial in terms of susceptibility to increased IOP.
引用
收藏
页数:6
相关论文
共 50 条
[31]   The evaluation of the effect of Nd-YAG capsulotomy on posterior ocular vascular structures by Optical coherence tomography angiography [J].
Urfalioglu, Selma ;
Ozdemir, Gokhan ;
Guler, Mete ;
Daghan, Betul ;
Oz, Furkan .
PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2023, 42
[32]   Use of topical brimonidine to prevent intraocular pressure elevations following Nd: YAG-laser posterior capsulotomy [J].
Singhal, Deepika ;
Desai, Roopali ;
Desai, Sejal ;
Shastri, Manisha ;
Saxena, Deepak .
JOURNAL OF PHARMACOLOGY & PHARMACOTHERAPEUTICS, 2011, 2 (02) :104-106
[33]   The Effects of Nd:YAG Laser Posterior Capsulotomy on Macular Thickness, Intraocular Pressure, and Visual Acuity [J].
Ari, Seyhmus ;
Cingu, Abdullah Kursat ;
Sahin, Alparslan ;
Cinar, Yasin ;
Caca, Ihsan .
OPHTHALMIC SURGERY LASERS & IMAGING, 2012, 43 (05) :395-400
[34]   The Effect of ND:YAG Laser Posterior Capsulotomy Size on Refraction, Intraocular Pressure, and Macular Thickness [J].
Karahan, Eyyup ;
Tuncer, Ibrahim ;
Zengin, Mehmet Ozgur .
JOURNAL OF OPHTHALMOLOGY, 2014, 2014
[35]   The role of anterior hyaloid face integrity on retinal complications during Nd: YAG laser capsulotomy [J].
Ozyol, Erhan ;
Ozyol, Pelin ;
Erdogan, Beyza Doganay ;
Onen, Mehmet .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (01) :71-75
[36]   Correlation between Filtering Bleb Clinical Morphology, Anterior Segment Optical Coherence Tomography Findings, and Intraocular Pressure [J].
Fakhraie, Ghasem ;
Kohansal, Sedigheh ;
Eslami, Yadollah ;
Jabbarvand, Mahmoud ;
Zarei, Reza ;
Rafizadeh, Seyed Mohsen ;
Rajabi, Mohammad Bagher ;
Fallah, Mohammad Reza ;
Moghimi, Sasan .
IRANIAN JOURNAL OF OPHTHALMOLOGY, 2011, 23 (04) :21-28
[37]   Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography [J].
Hong, Samin ;
Yi, Jeong-Ho ;
Kang, Sung Yong ;
Seong, Gong Je ;
Kim, Chan Yun .
YONSEI MEDICAL JOURNAL, 2009, 50 (04) :525-528
[38]   Anterior segment optical coherence tomography of acute primary angle closure [J].
Zhang, Hai Tao ;
Xu, Liang ;
Cao, Wei Fang ;
Wang, Ya Xing ;
Jonas, Jost B. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (06) :825-831
[39]   Comparative study of anterior segment measurement with Pentacam and anterior segment optical coherence tomography [J].
Fu, Jing ;
Wang, Xiaozhen ;
Li, Shuning ;
Wu, Gewei ;
Wang, Ningli .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2010, 45 (06) :627-631
[40]   Anterior Segment Optical Coherence Tomography for Canaliculitis [J].
Yoon, Sumin ;
Lee, Hyunkyu ;
Baek, Sehyun .
JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (01) :E59-E61