Intraocular pressure increase after Nd:YAG laser capsulotomy and anterior segment optical coherence tomography analysis

被引:0
|
作者
Keles, Ali [1 ]
Karaman, Suleyman Korhan [2 ]
机构
[1] Bilecik Seyh Edebali Univ, Fac Engn, Dept Ophthalmol, TR-11230 Bilecik, Turkiye
[2] Univ Hlth Sci, Ulucanlar Eye Training & Res Hosp, Dept Ophthalmol, Ankara, Turkiye
关键词
Anterior chamber angle; Anterior segment optical coherence tomography; Intraocular pressure; Nd:YAG laser capsulotomy; POSTERIOR CAPSULOTOMY; CHAMBER DEPTH; NEODYMIUM; REPRODUCIBILITY; REFRACTION; ELEVATION;
D O I
10.1007/s10103-023-03958-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study is to determine whether post-procedure intraocular pressure (IOP) increase is associated with the anterior chamber angle in cases of Neodymium: yttrium-aluminum garnet (Nd: YAG) laser capsulotomy. The study included 51 eyes with posterior capsule opacification. Initial IOP values of the patients were compared with IOP values without intraocular pressure-lowering administration at the end of the 1st hour, 1st day, 3rd day, and 7th day after Nd:YAG laser capsulotomy. The anterior segment angle configuration was evaluated using anterior segment optical coherence tomography analysis without dilatation before the procedure. The anterior chamber angle (ACA) and angle opening distances of 500 and 750 mu m (AOD500 and AOD750) in the nasal and temporal quadrants were examined. The mean pre-laser IOP value only increased significantly at 1st hour post-laser (13.02 +/- 3.02 mmHg vs 14.16 +/- 4.07 mmHg, p = 0.016). In eyes with ACA below 40 degrees in both the nasal and temporal quadrants, mean IOP increased significantly at 1st hour post-laser (p = 0.025 and p = 0.032, respectively), while it was not significant in eyes with ACA above 40 degrees (p > 0.05). No correlation was found between ACA, AOD500, and AOD750 values and IOP changes at the first hour (p > 0.05). Except for the first hour after Nd:YAG laser capsulotomy, no significant increase in IOP was observed. This elevation was higher in eyes with ACA less than 40 degrees. In patients with a narrow ACA, first-hour follow-up may be beneficial in terms of susceptibility to increased IOP.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Evaluation of the anterior segment parameters after Nd: YAG laser Capsulotomy: Effect the design of intraocular lens Haptic
    Akmaz, Berkay
    Akay, Fahrettin
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2018, 34 (02) : 322 - 327
  • [2] Anterior Segment Optical Coherence Tomography Assessment After Laser Capsulotomy in Pseudophakic Eyes With Pseudoexfoliation
    Eliacik, Mustafa
    Erdur, Sevil Karaman
    Gulkilik, Gokhan
    Ozsutcu, Mustafa
    Aras, Cengiz
    Bayramlar, Huseyin
    Aslan, Cemile Anil
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2016, 42 (05): : 318 - 321
  • [3] Rise Of Intraocular Pressure After Nd: Yag Laser Capsulotomy
    Shams, Asma
    Das, Narain
    Kumar, Jai
    Khan, Beensih
    Bhatti, M. Nasir
    Bin Tariq, Anas
    Anwar, Adnan
    ANNALS ABBASI SHAHEED HOSPITAL & KARACHI MEDICAL & DENTAL COLLEGE, 2021, 26 (04): : 198 - 203
  • [4] Intraocular Lens Position and Anterior Chamber Parameters Evaluation After Nd:YAG Laser Posterior Capsulotomy for Posterior Capsular Opacification Using Anterior Segment Swept-Source Optical Coherence Tomography
    Joao, Marina Delgado
    Costa, Jorge Vasco
    Monteiro, Tiago
    Franqueira, Nuno
    Correia, Fernando Faria
    Vaz, Fernando
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 153 - 159
  • [5] Bleb failure and intraocular pressure rise following Nd: Yag laser capsulotomy
    Diagourtas, Andreas
    Petrou, Petros
    Georgalas, Ilias
    Oikonomakis, Kostantinos
    Giannakouras, Panagiotis
    Vergados, Athanasios
    Papaconstantinou, Dimitrios
    BMC OPHTHALMOLOGY, 2017, 17
  • [6] Evaluation of the Impact of Nd:YAG Laser Posterior Capsulotomy on Ocular Pulse Amplitude and Anterior Segment Morphology
    Pekel, Gokhan
    Yagci, Ramazan
    Acer, Semra
    Ozdemir, Seyfullah
    Sayin, Nihat
    LASERS IN SURGERY AND MEDICINE, 2014, 46 (07) : 553 - 557
  • [7] The effects of Nd:YAG laser capsulotomy on anterior segment parameters in patients with posterior capsular opacification
    Oztas, Zafer
    Palamar, Melis
    Afrashi, Filiz
    Yagci, Ayse
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2015, 98 (02) : 168 - 171
  • [8] Anterior Segment Optical Coherence Tomography Measurement After Neodymium-Yttrium-Aluminum-Garnet Laser Capsulotomy
    Eliacik, Mustafa
    Bayramlar, Huseyin
    Erdur, Sevil Karaman
    Demirci, Goktug
    Gulkilik, Gokhan
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (05) : 994 - 998
  • [9] Effect of Nd:YAG Laser Posterior Capsulotomy on Intraocular Pressure
    Mehmood, Faisal
    Mazhar, Syed Abdullah
    Farooq, Nesr
    Zahid, Sehar
    Masood, Hifza
    Iqbal, Nabeel
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2022, 16 (01): : 109 - 110
  • [10] The Impact of Nd:YAG Capsulotomy on Foveal Thickness Measurement by Optical Coherence Tomography
    Altiparmak, Ugur E.
    Ersoz, Ibrahim
    Hazirolan, Dicle
    Koklu, Burcin
    Kasim, Remzi
    Duman, Sunay
    OPHTHALMIC SURGERY LASERS & IMAGING, 2010, 41 (01) : 67 - 71