Accurate mass measurements and ultrahigh-resolution: evaluation of different mass spectrometers for daily routine analysis of small molecules in negative electrospray ionization mode

被引:0
作者
Nuria Cortés-Francisco
Cintia Flores
Encarnación Moyano
Josep Caixach
机构
[1] IDAEA-CSIC,Mass Spectrometry Laboratory/Organic Pollutants
[2] University of Barcelona,Department of Analytical Chemistry
来源
Analytical and Bioanalytical Chemistry | 2011年 / 400卷
关键词
Ultrahigh-resolution; Accurate mass measurements; Molecular formulae determination; Small organic compounds; TOF; Orbitrap;
D O I
暂无
中图分类号
学科分类号
摘要
Six mass spectrometers based on different mass analyzer technologies, such as time-of-flight (TOF), hybrid quadrupole-TOF (Q-TOF), orbitrap, Fourier transform ion cyclotron resonance (FT-ICR), and triple quadrupole (QqQ), installed at independent laboratories have been tested during a single day of work for the analysis of small molecules in negative electrospray ionization (ESI) mode. The uncertainty in the mass measurements obtained from each mass spectrometer has been determined by taking the precision and accuracy of replicate measurements into account. The present study is focused on calibration processes (before, after, and during the mass measurement), the resolving power of the mass spectrometers, and the data processing for obtaining elemental formulae. The mass range between m/z 100 and 600 has been evaluated with a mix of four standards. This mass range includes small molecules usually detected in food and environmental samples. Negative ESI has been tested as there is almost no data on accurate mass (AM) measurements in this mode. Moreover, it has been used because it is the ESI mode for analysis of many compounds, such as pharmaceutical, herbicides, and fluorinated compounds. Natural organic matter has been used to demonstrate the significance of ultrahigh-resolution in complex mixtures. Sub-millidalton accuracy and precision have been obtained with Q-TOF, FT-ICR, and orbitrap achieving equivalent results. Poorer accuracy and precision have been obtained with the QqQ used: 11 mDa root-mean-square error and 6–11 mDa standard deviation. Some advice and requirements for daily AM routine analysis are also discussed here.
引用
收藏
页码:3595 / 3606
页数:11
相关论文
共 83 条
  • [1] Bristow AWT(2006)Accurate mass measurement for the determination of elemental formula-A tutorial Mass Spectrom Rev 25 99-111
  • [2] Brunnée C(1987)The ideal mass analyzer: fact or fiction? Int J Mass Spectrom Ion Process 76 125-237
  • [3] Ow SY(2010)Balancing robust quantification and identification for iTRAQ: application of UHR-ToF MS Proteomics 10 1-9
  • [4] Noirel J(2001)Accurate mass liquid chromatography/mass spectrometry on quadrupole orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 2. Applications using the dual-electrospray ion source Anal Chem 73 2605-2612
  • [5] Salim M(2005)Use of quadrupole time-of-flight mass spectrometry in the elucidation of unknown compounds present in environmental water Rapid Commun Mass Spectrom 19 169-178
  • [6] Evans C(2003)Exact mass measurement on an electrospray ionization time-of-flight mass spectrometer: error distribution and selective averaging J Mass Spectrom 38 1043-1053
  • [7] Watson R(2006)From mass to structure: an aromaticity index for high-resolution mass data of natural organic matter Rapid Commun Mass Spectrom 20 926-932
  • [8] Wright PC(2002)High resolution Fourier transform ion cyclotron resonance mass spectrometry of hummic and fulvic acids: improvements and comparisons Anal Chem 74 413-419
  • [9] Wolff JC(2008)Advanced characterization of marine dissolved organic matter by combining reversed-phase liquid chromatography and FT-ICR-MS Mar Chem 111 233-241
  • [10] Eckers C(2001)Elemental composition analysis of processed and unprocessed diesel fuel by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry Energy Fuels 15 1186-1193