Overhead transmission line performance with respect to grounding impedance on alpine terrain

被引:0
|
作者
L. Schwalt
S. Pack
J. Plesch
机构
[1] Graz University of Technology,Institute of High Voltage Engineering and System Performance
来源
e & i Elektrotechnik und Informationstechnik | 2020年 / 137卷
关键词
transient measurement; lightning discharge; transmission line; grounding impedance;
D O I
暂无
中图分类号
学科分类号
摘要
The present paper shows a study case of transient effects of direct and indirect lightning discharges on overhead transmission lines with respect to actual grounding impedances of the transmission line system. The transient measurement data was gathered from two 400 kV double-system overhead lines equipped with an overhead ground wire. Additionally installed RC dividers are used to perform transient voltage measurements with high accuracy in amplitude and frequency. The pairing of electric, time and geographic parameters of the used datasets provides the basis for an analysis of the performance of the overhead lines and the high-voltage system influenced by lightning discharges. For this case study, a novel approach is presented where the actual tower-footing grounding impedance of the two systems is related to the transient effects of direct and indirect lightning discharges on the lines as new parameter. The topic, whether it be exposed overhead transmission line systems in the alpine area or line sections with high grounding impedances that show a higher probability of power system faults, is analysed and interpreted in this case study.
引用
收藏
页码:450 / 454
页数:4
相关论文
共 50 条
  • [41] TRANSMISSION-LINE IMPEDANCE
    SOMLO, PI
    WIRELESS WORLD, 1975, 81 (1478): : 467 - 467
  • [42] IMPEDANCE OF A TRANSMISSION-LINE
    ARATARI, R
    WIRELESS WORLD, 1975, 81 (1472): : 168 - 168
  • [43] OVERHEAD TRANSMISSION - TRANSMISSION-LINE MECHANICAL RESEARCH FACILITY
    LYONS, P
    EPRI JOURNAL, 1985, 10 (04): : 46 - 47
  • [44] TEST LINE EXPERIENCE WITH HVDC OVERHEAD TRANSMISSION
    BAILEY, BM
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (07): : 1625 - &
  • [46] Overview of different overhead transmission line conductors
    Rashmi
    Shivashankar, G. S.
    Poornima
    MATERIALS TODAY-PROCEEDINGS, 2017, 4 (10) : 11318 - 11324
  • [47] Measurement and Analysis of Impulse Grounding Impedance for UHV Transmission Tower
    Si, W. R.
    Fu, C. Z.
    Wu, T. Y.
    Wang, S. J.
    Yuan, P.
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [48] Research on Impulse Impedance Measurement for Grounding Device of Transmission Tower
    Si Wen-Rong
    Fu Chen-Zhao
    Lu Bing-Bing
    Guo Xiang
    Xu Zhi-Bing
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [49] STUDY ON OVERHEAD TRANSMISSION LINE ON-LINE MONITORING TECHNOLOGY
    Yang, Zhiwang
    Zivlak, Nikola
    Xu, Ming
    Ljubicic, Marko
    THERMAL SCIENCE, 2016, 20 : S383 - S391
  • [50] Composite Grounding Application of Transmission Line Tower with Flexible Graphite Grounding Material
    Liu, Hongtao
    Zhang, Lei
    Xiong, Jia
    Cui, Zhenxing
    Yang, Qi
    2ND INTERNATIONAL CONFERENCE ON DESIGN, MATERIALS, AND MANUFACTURING, 2017, 220