Deformable Registration for Longitudinal Breast MRI Screening

被引:0
作者
Hatef Mehrabian
Lara Richmond
Yingli Lu
Anne L. Martel
机构
[1] Sunnybrook Research Institute,Physical Sciences
[2] Sunnybrook Health Sciences Centre,Department of Medical Imaging
[3] University of Toronto,Department of Medical Biophysics
来源
Journal of Digital Imaging | 2018年 / 31卷
关键词
Breast MRI; Non-rigid registration; Finite element analysis; Elastix;
D O I
暂无
中图分类号
学科分类号
摘要
MRI screening of high-risk patients for breast cancer provides very high sensitivity, but with a high recall rate and negative biopsies. Comparing the current exam to prior exams reduces the number of follow-up procedures requested by radiologists. Such comparison, however, can be challenging due to the highly deformable nature of breast tissues. Automated co-registration of multiple scans has the potential to aid diagnosis by providing 3D images for side-by-side comparison and also for use in CAD systems. Although many deformable registration techniques exist, they generally have a large number of parameters that need to be optimized and validated for each new application. Here, we propose a framework for such optimization and also identify the optimal input parameter set for registration of 3D T1-weighted MRI of breast using Elastix, a widely used and freely available registration tool. A numerical simulation study was first conducted to model the breast tissue and its deformation through finite element (FE) modeling. This model generated the ground truth for evaluating the registration accuracy by providing the deformation of each voxel in the breast volume. An exhaustive search was performed over various values of 7 registration parameters (4050 different combinations of parameters were assessed) and the optimum parameter set was determined. This study showed that there was a large variation in the registration accuracy of different parameter sets ranging from 0.29 mm to 2.50 mm in median registration error and 3.71 mm to 8.90 mm in 95 percentile of the registration error. Mean registration errors of 0.32 mm, 0.29 mm, and 0.30 mm and 95 percentile errors of 3.71 mm, 5.02 mm, and 4.70 mm were obtained by the three best parameter sets. The optimal parameter set was applied to consecutive breast MRI scans of 13 patients. A radiologist identified 113 landmark pairs (~ 11 per patient) which were used to assess registration accuracy. The results demonstrated that using the optimal registration parameter set, a registration accuracy (in mm) of 3.4 [1.8 6.8] was achieved.
引用
收藏
页码:718 / 726
页数:8
相关论文
共 50 条
  • [31] Personal History of Premenopausal Breast Cancer as a Risk Factor for Referral to Screening Breast MRI
    Destounis, Stamatia
    Arieno, Andrea
    Morgan, Renee
    ACADEMIC RADIOLOGY, 2016, 23 (03) : 353 - 357
  • [32] Deep Diffusion MRI Registration (DDMReg): A Deep Learning Method for Diffusion MRI Registration
    Zhang, Fan
    Wells, William M., III
    O'Donnell, Lauren J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (06) : 1454 - 1467
  • [33] WAVELET-BASED VARIATIONAL DEFORMABLE REGISTRATION FOR ULTRASOUND
    Hefny, Mohamed S.
    Ellis, Randy E.
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 1017 - 1020
  • [34] Robust deformable image registration using prior shape information for atlas to patient registration
    Ellingsen, Lotta M.
    Chintalapani, Gouthami
    Taylor, Russell H.
    Prince, Jerry L.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2010, 34 (01) : 79 - 90
  • [35] On Finite Difference Jacobian Computation in Deformable Image Registration
    Liu, Yihao
    Chen, Junyu
    Wei, Shuwen
    Carass, Aaron
    Prince, Jerry
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 2024, 132 (09) : 3678 - 3688
  • [36] VoxelMorph: A Learning Framework for Deformable Medical Image Registration
    Balakrishnan, Guha
    Zhao, Amy
    Sabuncu, Mert R.
    Guttag, John
    Dalca, Adrian, V
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (08) : 1788 - 1800
  • [37] Range Scan Registration Using Reduced Deformable Models
    Chang, W.
    Zwicker, M.
    COMPUTER GRAPHICS FORUM, 2009, 28 (02) : 447 - 456
  • [38] Validation of three deformable image registration algorithms for the thorax
    Latifi, Kujtim
    Zhang, Geoffrey
    Stawicki, Marnix
    van Elmpt, Wouter
    Dekker, Andre
    Forster, Kenneth
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 19 - 30
  • [39] Assessment of a commercially available automatic deformable registration system
    Fallone, B. Gino
    Rivest, D. Ryan C.
    Riauka, Terence A.
    Murtha, Albert D.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (03): : 101 - 123
  • [40] Hierachical Spherical Harmonics Based Deformable HARDI Registration
    Yap, Pew-Thian
    Chen, Yasheng
    An, Hongyu
    Gilmore, John H.
    Lin, Weili
    Shen, Dinggang
    MEDICAL IMAGING AND AUGMENTED REALITY, 2010, 6326 : 228 - +