Deformable Registration for Longitudinal Breast MRI Screening

被引:0
|
作者
Hatef Mehrabian
Lara Richmond
Yingli Lu
Anne L. Martel
机构
[1] Sunnybrook Research Institute,Physical Sciences
[2] Sunnybrook Health Sciences Centre,Department of Medical Imaging
[3] University of Toronto,Department of Medical Biophysics
来源
Journal of Digital Imaging | 2018年 / 31卷
关键词
Breast MRI; Non-rigid registration; Finite element analysis; Elastix;
D O I
暂无
中图分类号
学科分类号
摘要
MRI screening of high-risk patients for breast cancer provides very high sensitivity, but with a high recall rate and negative biopsies. Comparing the current exam to prior exams reduces the number of follow-up procedures requested by radiologists. Such comparison, however, can be challenging due to the highly deformable nature of breast tissues. Automated co-registration of multiple scans has the potential to aid diagnosis by providing 3D images for side-by-side comparison and also for use in CAD systems. Although many deformable registration techniques exist, they generally have a large number of parameters that need to be optimized and validated for each new application. Here, we propose a framework for such optimization and also identify the optimal input parameter set for registration of 3D T1-weighted MRI of breast using Elastix, a widely used and freely available registration tool. A numerical simulation study was first conducted to model the breast tissue and its deformation through finite element (FE) modeling. This model generated the ground truth for evaluating the registration accuracy by providing the deformation of each voxel in the breast volume. An exhaustive search was performed over various values of 7 registration parameters (4050 different combinations of parameters were assessed) and the optimum parameter set was determined. This study showed that there was a large variation in the registration accuracy of different parameter sets ranging from 0.29 mm to 2.50 mm in median registration error and 3.71 mm to 8.90 mm in 95 percentile of the registration error. Mean registration errors of 0.32 mm, 0.29 mm, and 0.30 mm and 95 percentile errors of 3.71 mm, 5.02 mm, and 4.70 mm were obtained by the three best parameter sets. The optimal parameter set was applied to consecutive breast MRI scans of 13 patients. A radiologist identified 113 landmark pairs (~ 11 per patient) which were used to assess registration accuracy. The results demonstrated that using the optimal registration parameter set, a registration accuracy (in mm) of 3.4 [1.8 6.8] was achieved.
引用
收藏
页码:718 / 726
页数:8
相关论文
共 50 条
  • [1] Deformable Registration for Longitudinal Breast MRI Screening
    Mehrabian, Hatef
    Richmond, Lara
    Lu, Yingli
    Martel, Anne L.
    JOURNAL OF DIGITAL IMAGING, 2018, 31 (05) : 718 - 726
  • [2] Fully automated deformable registration of breast DCE-MRI and PET/CT
    Dmitriev, I. D.
    Loo, C. E.
    Vogel, W. V.
    Pengel, K. E.
    Gilhuijs, K. G. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04) : 1221 - 1233
  • [3] Longitudinal registration of T1-weighted breast MRI: A registration algorithm (FLIRE) and clinical application
    Tong, Michelle W.
    Yu, Hon J.
    Andreassen, Maren M. Sjaastad
    Loubrie, Stephane
    Rodriguez-Soto, Ana E.
    Seibert, Tyler M.
    Rakow-Penner, Rebecca
    Dale, Anders M.
    MAGNETIC RESONANCE IMAGING, 2024, 113
  • [4] Using manual prostate contours to enhance deformable registration of endorectal MRI
    Cheung, M. R.
    Krishnan, K.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2012, 108 (01) : 330 - 337
  • [5] Deformable Slice-to-Volume Registration for Motion Correction of Fetal Body and Placenta MRI
    Uus, Alena
    Zhang, Tong
    Jackson, Laurence H.
    Roberts, Thomas A.
    Rutherford, Mary A.
    Hajnal, Joseph, V
    Deprez, Maria
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (09) : 2750 - 2759
  • [6] Clinical evaluation of an MRI-to-ultrasound deformable image registration algorithm for prostate brachytherapy
    Shaaer, Amani
    Davidson, Melanie
    Semple, Mark
    Nicolae, Alexandru
    Mendez, Lucas Castro
    Chung, Hans
    Loblaw, Andrew
    Tseng, Chia-Lin
    Morton, Gerard
    Ravi, Ananth
    BRACHYTHERAPY, 2019, 18 (01) : 95 - 102
  • [7] FAST MRI breast screening revisited
    Jain, Manish
    Jain, Arushi
    Hyzy, Marek D.
    Werth, Graziella
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (01) : 24 - 28
  • [8] Recent Trends in Screening Breast MRI
    Lee, Michelle, V
    Aharon, Shani
    Kim, Kevin
    Sunn Konstantinoff, Katerina
    Appleton, Catherine M.
    Stwalley, Dustin
    Olsen, Margaret A.
    JOURNAL OF BREAST IMAGING, 2022, 4 (01) : 39 - 47
  • [9] Auditing a Breast MRI Practice: Performance Measures for Screening and Diagnostic Breast MRI
    Niel, Bethany L.
    Gavenonis, Sara C.
    Motazedi, Tina
    Chubiz, Jessica Cott
    Halpern, Elkan P.
    Rafferty, Elizabeth A.
    Lee, Janie M.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2014, 11 (09) : 883 - 889
  • [10] Changing Paradigms in Breast Cancer Screening: Abbreviated Breast MRI
    Mootz, Ann R.
    Madhuranthakam, Ananth J.
    Dogan, Basak E.
    EUROPEAN JOURNAL OF BREAST HEALTH, 2019, 15 (01) : 1 - 6