Automated multi-column chromatographic separation of short-lived 242g, 240Am, 237U and 72Ga from fresh fission products

被引:0
作者
Jinlong Fan
Yufeng Wang
Zhiming Li
Xiufang Zhai
Xiangbo Zhang
Pei Shang
Li Duan
Gongshuo Yu
Jianfeng Liang
Tao Bai
机构
[1] Northwest Institute of Nuclear Technology,
来源
Journal of Radioanalytical and Nuclear Chemistry | 2023年 / 332卷
关键词
Short-lived Am; Short-lived U; Short-lived Ga; Activation product; Automated separation; Column chromatography; Fission products;
D O I
暂无
中图分类号
学科分类号
摘要
We present an automated separation method to simultaneously isolate short-lived activation products 242g, 240Am, 237U, 72Ga from fresh fission products prior to gamma spectrometric analysis. On the basis of multi-column chromatographic units (HDEHP resin, TBP resin, DGA resin, TEVA resin, Al2O3, activated carbon) assembly, smart media compatibility between adjacent columns, chromatographic conditions optimization and process automation design, a modularized and streamline separation procedure was developed. The established method allows better recoveries of 93%, 91% and 97% for americium, uranium and gallium separately and excellent decontamination factors of more than 105 for fission products even for large volume of samples. Because of highly efficient removal of interferents, this method coupled with well-type high-purity germanium (HPGe) gamma spectrometers achieved highly sensitive and selective analysis of activation products in spiked complicated matrix samples.
引用
收藏
页码:2667 / 2678
页数:11
相关论文
共 168 条
  • [1] Douglas M(2009)Separation and quantification of chemically diverse analytes in neutron irradiated fissile materials J Radioanal Nucl Chem 282 63-68
  • [2] Friese JI(2015)Integrated separation scheme for measuring a suite of fission and activation products from a fresh mixed fission and activation product sample J Radioanal Nucl Chem 304 509-515
  • [3] Greenwood LR(2016)A chemical separation procedure using ionic liquid extraction for J Radioanal Nucl Chem 307 2479-2485
  • [4] Farmer OT(2017)Fe and J Radioanal Nucl Chem 314 2501-2506
  • [5] Thomas ML(2019)Fe quantification J Radioanal Nucl Chem 322 281-289
  • [6] Maiti TC(2021)Activation product analysis in a mixed sample containing both fission and neutron activation products J Radioanal Nucl Chem 327 21-30
  • [7] Finn EC(2009)Rapid activation product separations from fission products and soil matrixes At Energ 107 69-72
  • [8] Garofoli SJ(2015)Potential defect structure effects in the volatility separation of sub-picogram quantities of fission and activation products from an irradiated UO Ann Nucl Energy 83 8-13
  • [9] Gassman PL(2016) matrix Phys Rev C 93 014610-628
  • [10] Huff MM(1978)Gallium removal during pyrochemical reprocessing of weapons plutonium into oxide fuel J Nucl Sci Technol 15 626-383