The image reconstruction for fluorescence molecular tomography via a non-uniform mesh

被引:0
作者
Bin Wang
Pu Jiao
Huangjian Yi
Xin Cao
Fengjun Zhao
Yuqing Hou
Xiaowei He
机构
[1] Northwest University,School of Information Sciences and Technology
来源
Optical Review | 2020年 / 27卷
关键词
Optical molecular imaging; Fluorescence molecular tomography; Finite element method; Non-uniform mesh;
D O I
暂无
中图分类号
学科分类号
摘要
As an optical molecular imaging modality, fluorescence molecular tomography (FMT) can monitor the activities of organisms in vivo at the molecular and cellular levels. However, the recovered image quality is affected by mesh voxel when the finite element method is utilized to recover the fluorescence probe. The target localization is likely to deviate from the actual target under the coarse mesh, but using the fine mesh will increase the number of unknowns, which makes the computational burden heavier and further aggravate the ill-posedness. To solve the problem, a reconstruction strategy using a non-uniform mesh for FMT is developed in this paper. The numerical experiment and physical experiment validated that the strategy is capable and effective for FMT.
引用
收藏
页码:31 / 38
页数:7
相关论文
共 96 条
[1]  
Ntziachristos V(2002)Fluorescence molecular tomography resolves protease activity in vivo Nat Med. 8 757-761
[2]  
Tung C-H(2013)Accelerated image reconstruction in fluorescence molecular tomography using dimension reduction Biomed Opt Express. 4 1-14
[3]  
Bremer C(2004)Visualization of antitumor treatment by means of fluorescence molecular tomography with an annexin V-Cy5.5 conjugate Proc Natl Acad Sci USA 101 12294-12299
[4]  
Weissleder R(2012)Pre-clinical optical molecular imaging in the lung: technological challenges and future prospects J Thorac Dis 4 556-557
[5]  
Xu C(2016)A sparsity-constrained preconditioned Kaczmarz reconstruction method for fluorescence molecular tomography BioMed Res Int 2016 2063-2079
[6]  
Xin W(2017)Enhancement of the localization and quantitative performance of fluorescence molecular tomography by using linear nBorn method Opt Express 25 217-229
[7]  
Zhang B(2010)Discretization error analysis and adaptive meshing algorithms for fluorescence diffuse optical tomography: Part I IEEE Trans Med Imaging. 29 230-245
[8]  
Fei L(2010)Discretization error analysis and adaptive meshing algorithms for fluorescence diffuse optical tomography: Part II IEEE Trans Med Imaging 29 1094-1111
[9]  
Luo J(2010)Discretization error analysis and adaptive meshing algorithms for fluorescence diffuse optical tomography in the presence of measurement noise IEEE Trans Image Process 20 9722-9730
[10]  
Jing B(2007)Adaptive-mesh-based algorithm for fluorescence molecular tomography using an analytical solution Opt Express. 15 465-473