Voltammetric determination of trace level of cadmium in mussels and seawaters by a lacunar apatite-modified carbon electrode

被引:0
作者
Sara Lahrich
Sana Saqrane
Bouchaib Manoun
Moulay Abderrahim El Mhammedi
机构
[1] Université Sultan Moulay Slimane,Laboratoire de Chimie, Modélisation Et Sciences de L’Environnement, Faculté Polydisciplinaire
[2] Université Sultan Moulay Slimane,Laboratoire de Sciences Des Matériaux, Des Milieux Et de La Modélisation, Faculté Polydisciplinaire
来源
Journal of Food Measurement and Characterization | 2019年 / 13卷
关键词
Apatite; Mussels; Seawater; Cadmium; Differential pulse anodic stripping voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
An electrochemical sensor was fabricated by potassium lacunar apatite (KCaAP). This sensor, coupled with differential pulse anodic stripping voltammetry, could provide a means for a relatively inexpensive detector for trace levels of cadmium. The analytical performance was evaluated with respect to the quantity of modifier in the paste, preconcentration time and the stripping voltammetric parameters. A linear calibration graph was obtained in the concentration range 7.0 × 10–7–1.0 × 10–4 mol L−1 Cd (II) with a detection limit of 4.86 × 10−8 mol L−1. For eight repetitions, the differential pulse voltammetric response was repeated with 7.15% and 4.69% expressed as relative standard deviations in 9.0 × 10−6 and 9.0 × 10−5 mol L−1 of cadmium (II), respectively. The lacunar apatite modified carbon paste electrode (KCaAP-CPE) was applied to the detection of cadmium content in mussels and seawater samples with satisfactory results.
引用
收藏
页码:2318 / 2327
页数:9
相关论文
共 50 条
[31]   Nano zinc ferrite modified electrode as a novel electrochemical sensing platform in simultaneous measurement of trace level lead and cadmium [J].
Kumar, Arun N. S. ;
Ashoka, S. ;
Malingappa, Pandurangappa .
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2018, 6 (06) :6939-6946
[32]   Determination of lead and cadmium using a polycyclodextrin-modified carbon paste electrode with anodic stripping voltammetry [J].
Gabriela Roa ;
M. T. Ramírez-Silva ;
M. A. Romero-Romo ;
Laura Galicia .
Analytical and Bioanalytical Chemistry, 2003, 377 :763-769
[33]   Determination of lead and cadmium using a polycyclodextrin-modified carbon paste electrode with anodic stripping voltammetry [J].
Roa, G ;
Ramírez-Silva, MT ;
Romero-Romo, MA ;
Galicia, L .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (04) :763-769
[34]   Electrochemical Determination of Trace Cadmium in Soil by a Bismuth Film/Graphene-β-cyclodextrin-Nafion Composite Modified Electrode [J].
Zhao, Guo ;
Wang, Hui ;
Liu, Gang .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (03) :1840-1851
[35]   Ultra trace level square wave anodic stripping voltammetric sensing of mercury(II) ions in environmental samples using a Schiff base-modified carbon paste electrode [J].
Hashemi, Seyed Ebrahim ;
Payehghadr, Mahmood ;
Es'haghi, Zarrin ;
Kargar, Hadi .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2019, 99 (12) :1148-1163
[36]   Anodic Stripping Voltammetric Determination of Iron(II) at a Carbon Paste Electrode Modified with Dithiodianiline (DTDA) and Gold Nanoparticles (GNP) [J].
Gholivand, Mohammad Bagher ;
Geravandi, Behrooz ;
Parvin, Mohammad Hadi .
ELECTROANALYSIS, 2011, 23 (06) :1345-1351
[37]   Potentiometric Sensor for Trace Level Analysis of Copper Based on Carbon Paste Electrode Modified With Multi-walled Carbon Nanotubes [J].
Soleimani, Majid ;
Afshar, Majid Ghahraman .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (06) :8719-8729
[38]   Mercury-free simultaneous determination of cadmium and lead at a glassy carbon electrode modified with multi-wall carbon nanotubes [J].
Wu, KB ;
Hu, SS ;
Fei, JJ ;
Bai, W .
ANALYTICA CHIMICA ACTA, 2003, 489 (02) :215-221
[39]   Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry [J].
Honeychurch, KC ;
Hart, JP ;
Cowell, DC ;
Arrigan, DWM .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (03) :642-652
[40]   Simultaneous determination of cadmium (II) and lead (II) with clay nanoparticles and anthraquinone complexly modified glassy carbon electrode [J].
Yuan, S ;
Chen, WH ;
Hu, SH .
TALANTA, 2004, 64 (04) :922-928