Significant reduction in procedure duration in remote magnetic-guided catheter ablation of atrial fibrillation using the third-generation magnetic navigation system

被引:0
作者
Tilman Maurer
Christian Sohns
Sebastian Deiss
Laura Rottner
Peter Wohlmuth
Bruno Reißmann
Christian H. Heeger
Christine Lemes
Johannes Riedl
Francesco Santoro
Shibu Mathew
Andreas Metzner
Feifan Ouyang
Karl-Heinz Kuck
Erik Wissner
机构
[1] Asklepios Klinik St. Georg,Department of Cardiology
[2] University of Illinois at Chicago,Division of Cardiology
来源
Journal of Interventional Cardiac Electrophysiology | 2017年 / 49卷
关键词
Atrial fibrillation; Catheter ablation; Pulmonary vein isolation; Magnetic navigation;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:219 / 226
页数:7
相关论文
共 210 条
  • [1] Kirchhof P(2016)2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS Europace 18 1609-1678
  • [2] Benussi S(2010)Remote-controlled magnetic pulmonary vein isolation using a new irrigated-tip catheter in patients with atrial fibrillation Circ Arrhythm Electrophysiol 3 458-464
  • [3] Kotecha D(2015)Efficacy and safety of remote magnetic catheter navigation vs. manual steerable sheath-guided ablation for catheter ablation of atrial fibrillation: a case-control study Europace 17 232-238
  • [4] Ahlsson A(2014)Single-ring ablation compared with standard circumferential pulmonary vein isolation using remote magnetic catheter navigation J Interv Card Electrophysiol 41 75-82
  • [5] Atar D(2013)Remote magnetic with open-irrigated catheter vs. manual navigation for ablation of atrial fibrillation: a systematic review and meta-analysis Europace 15 1241-1248
  • [6] Casadei B(2013)Pulmonary vein anatomy predicts freedom from atrial fibrillation using remote magnetic navigation for circumferential pulmonary vein ablation Europace 15 1136-1142
  • [7] Castella M(2016)A comparison of remote magnetic irrigated tip ablation versus manual catheter irrigated tip catheter ablation with and without force sensing feedback J Cardiovasc Electrophysiol 27 S5-S10
  • [8] Diener HC(2010)Remote magnetic navigation with irrigated tip catheter for ablation of paroxysmal atrial fibrillation Circ Arrhythm Electrophysiol 3 585-589
  • [9] Heidbuchel H(2004)Initial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation Circulation 109 1472-1475
  • [10] Hendriks J(2014)Remote magnetic navigation for circumferential pulmonary vein ablation: single-catheter technique or additional use of a circular mapping catheter? J Interv Card Electrophysiol 41 65-73