Assessment of the real-time PCR and different digital PCR platforms for DNA quantification

被引:0
|
作者
Jernej Pavšič
Jana Žel
Mojca Milavec
机构
[1] National Institute of Biology,Department of Biotechnology and Systems Biology
[2] Jožef Stefan International Postgraduate School,undefined
来源
关键词
Digital PCR; Real-time PCR; Molecular diagnostics; Human cytomegalovirus; DNA quantification;
D O I
暂无
中图分类号
学科分类号
摘要
Digital PCR (dPCR) is beginning to supersede real-time PCR (qPCR) for quantification of nucleic acids in many different applications. Several analytical properties of the two most commonly used dPCR platforms, namely the QX100 system (Bio-Rad) and the 12.765 array of the Biomark system (Fluidigm), have already been evaluated and compared with those of qPCR. However, to the best of our knowledge, direct comparison between the three of these platforms using the same DNA material has not been done, and the 37 K array on the Biomark system has also not been evaluated in terms of linearity, analytical sensitivity and limit of quantification. Here, a first assessment of qPCR, the QX100 system and both arrays of the Biomark system was performed with plasmid and genomic DNA from human cytomegalovirus. With use of PCR components that alter the efficiency of qPCR, each dPCR platform demonstrated consistent copy-number estimations, which indicates the high resilience of dPCR. Two approaches, one considering the total reaction volume and the other considering the effective reaction size, were used to assess linearity, analytical sensitivity and variability. When the total reaction volume was considered, the best performance was observed with qPCR, followed by the QX100 system and the Biomark system. In contrast, when the effective reaction size was considered, all three platforms showed almost equal limits of detection and variability. Although dPCR might not always be more appropriate than qPCR for quantification of low copy numbers, dPCR is a suitable method for robust and reproducible quantification of viral DNA, and a promising technology for the higher-order reference measurement method.
引用
收藏
页码:107 / 121
页数:14
相关论文
共 50 条
  • [21] Comparison between RT droplet digital PCR and RT real-time PCR for quantification of noroviruses in oysters
    Persson, Sofia
    Eriksson, Ronnie
    Lowther, James
    Ellstrom, Patrik
    Simonsson, Magnus
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2018, 284 : 73 - 83
  • [22] Real-time PCR for quantification of Streptococcus mutans
    Yano, A
    Kaneko, N
    Ida, H
    Yamaguchi, T
    Hanada, N
    FEMS MICROBIOLOGY LETTERS, 2002, 217 (01) : 23 - 30
  • [23] Conventional PCR Detection and Real-Time PCR Quantification of Reniform Nematodes
    Sayler, Ronald J.
    Walker, Courtney
    Goggin, Fiona
    Agudelo, Paula
    Kirkpatrick, Terrence
    PLANT DISEASE, 2012, 96 (12) : 1757 - 1762
  • [24] Cytokine mRNA quantification by real-time PCR
    Stordeur, P
    Poulin, LF
    Craciun, L
    Zhou, L
    Schandené, L
    de Lavareille, A
    Goriely, S
    Goldman, M
    JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 259 (1-2) : 55 - 64
  • [25] Comparison of fluorometric and spectrophotometric DNA quantification for real-time quantitative PCR of degraded DNA
    Shokere, Luke A.
    Holden, Marcia J.
    Jenkins, G. Ronald
    FOOD CONTROL, 2009, 20 (04) : 391 - 401
  • [26] Real-Time PCR Quantification of Chloroplast DNA Supports DNA Barcoding of Plant Species
    Hitomi S. Kikkawa
    Kouichiro Tsuge
    Ritsuko Sugita
    Molecular Biotechnology, 2016, 58 : 212 - 219
  • [27] Real-Time PCR Quantification of Chloroplast DNA Supports DNA Barcoding of Plant Species
    Kikkawa, Hitomi S.
    Tsuge, Kouichiro
    Sugita, Ritsuko
    MOLECULAR BIOTECHNOLOGY, 2016, 58 (03) : 212 - 219
  • [28] Evaluation of different DNA sampling techniques for the application of the real-time PCR method for the quantification of cyanobacteria in water
    Schober, E
    Kurmayer, R
    LETTERS IN APPLIED MICROBIOLOGY, 2006, 42 (04) : 412 - 417
  • [29] Technical and clinical validation of three commercial real-time PCR kits for the diagnosis of neuroborreliosis in cerebrospinal fluid on three different real-time PCR platforms
    Maes, L.
    Carolus, T.
    De Preter, V.
    Ignoul, S.
    Cartuyvels, R.
    Braeken, L.
    D'Huys, P. -J.
    Saegeman, V.
    Kabamba, B.
    Raymaekers, M.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2017, 36 (02) : 273 - 279
  • [30] Technical and clinical validation of three commercial real-time PCR kits for the diagnosis of neuroborreliosis in cerebrospinal fluid on three different real-time PCR platforms
    L. Maes
    T. Carolus
    V. De Preter
    S. Ignoul
    R. Cartuyvels
    L. Braeken
    P.-J. D’Huys
    V. Saegeman
    B. Kabamba
    M. Raymaekers
    European Journal of Clinical Microbiology & Infectious Diseases, 2017, 36 : 273 - 279