Magnetic beads retention device for sandwich immunoassay: comparison of off-chip and on-chip antibody incubation

被引:0
|
作者
F. Lacharme
C. Vandevyver
M. A. M. Gijs
机构
[1] Ecole Polytechnique Fédérale de Lausanne (EPFL),Laboratory of Microsystems
[2] Ecole Polytechnique Fédérale de Lausanne (EPFL),Research Commission EPFL
来源
Microfluidics and Nanofluidics | 2009年 / 7卷
关键词
Microfluidics; Immunoassay; ELISA; Antibody; Magnetism; Magnetic microbeads; Self-assembly; Microchip; Nanoparticles;
D O I
暂无
中图分类号
学科分类号
摘要
We use magnetic microbeads, which are magnetically self-assembled in chains in a microfluidic chip, as reaction substrates to implement two different sandwich immunoassay protocols for the detection of mouse monoclonal target antibodies. The magnetic chains form when the chip is placed in a magnetic field, and are geometrically trapped and accurately positioned in a microchannel with periodically enlarged cross-sections. In the first immunoassay protocol, capture and target antibodies are incubated off-chip, while exposure to the detection antibody is performed on-chip. In the second protocol, the complete immunoassay is fully executed on-chip. In the ‘off-chip incubation–on-chip detection’ protocol, antibodies can be detected down to a concentration of 50 ng/mL in a total assay time of 120 min, while consuming 1.5 mL of target antibody solution. Using the full on-chip protocol, our system is able to detect target antibodies in the range of a few ng/mL in 30 min, using only a few tens of nanoliters of target antibody solution and reagents. The ‘off-chip incubation–on-chip detection’ protocol is also applied for dosing antibodies obtained from the supernatant of a cell culture medium.
引用
收藏
相关论文
共 50 条
  • [31] Tailor designed exclusive carbon nanomaterial electrodes for off-chip and on-chip electrochemical detection
    Aída Martín
    Alberto Escarpa
    Microchimica Acta, 2017, 184 : 307 - 313
  • [32] Off-chip control flow checking of on-chip processor-cache instruction stream
    Rota, Federico
    Dutt, Shantanu
    Krishna, Sahithi
    21ST IEEE INTERNATIONAL SYMPOSIUM ON DEFECT AND FAULT-TOLERANCE IN VLSI SYSTEMS, PROCEEDINGS, 2006, : 507 - +
  • [33] Tailor designed exclusive carbon nanomaterial electrodes for off-chip and on-chip electrochemical detection
    Martin, Aida
    Escarpa, Alberto
    MICROCHIMICA ACTA, 2017, 184 (01) : 307 - 313
  • [34] On-Chip Manipulation of Magnetic Beads for Integrated Immunosensor
    Ishikawa, Tomohiro
    Lee, Jaesung
    Miyake, Ryo
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2014, 97 (11) : 37 - 41
  • [35] On-chip manipulation of magnetic beads for integrated immunosensor
    Ishikawa, T. (ishikawa@mems.mech.tohoku.ac.jp), 1600, Institute of Electrical Engineers of Japan (133):
  • [36] Complete Time-Domain Diode Modeling: Application to Off-Chip and On-Chip Protection Devices
    Ben M'Hamed, Bruno
    Torres, Francois
    Reineix, Alain
    Hoffmann, Patrick
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2011, 53 (02) : 349 - 365
  • [37] Programmable on-chip and off-chip network architecture on demand for flexible optical intra-Datacenters
    Rofoee, Bijan Rahimzadeh
    Zervas, Georgios
    Yan, Yan
    Amaya, Norberto
    Qin, Yixuan
    Simeonidou, Dimitra
    OPTICS EXPRESS, 2013, 21 (05): : 5475 - 5480
  • [38] Using conduction modes basis functions for efficient electromagnetic analysis of on-chip and off-chip interconnect
    Daniel, L
    Sangiovanni-Vincentelli, A
    White, J
    38TH DESIGN AUTOMATION CONFERENCE PROCEEDINGS 2001, 2001, : 563 - 566
  • [39] On-chip differential and common mode voltage measurement using off-chip referenced twin probing
    Yamanaga, Koh
    Sato, Takashi
    Masu, Kazuya
    2008 IEEE WORKSHOP ON SIGNAL PROPAGATION ON INTERCONNECTS, 2008, : 55 - 58
  • [40] Modeling and Co-Simulation of I/O Interconnects for On-Chip and Off-Chip EMI Prediction
    Kwak, SangKeun
    Jo, Jeongmin
    Kim, SoYoung
    2012 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2012, : 821 - 824