Optimization of NMR analysis of biological fluids for quantitative accuracy

被引:0
作者
Erik J. Saude
Carolyn M. Slupsky
Brian D. Sykes
机构
[1] University of Alberta,CIHR Group in Protein Structure and Function, Department of Biochemistry, Faculty of Medicine
[2] Chenomx Inc.,Metabolomics Centre, Department of Medicine
[3] University of Alberta,undefined
来源
Metabolomics | 2006年 / 2卷
关键词
NMR; metabonomics; quantitation; accuracy; metabolite;
D O I
暂无
中图分类号
学科分类号
摘要
With the rising interest in the use of nuclear magnetic resonance (NMR) for the study of biological fluids such as urine and serum for metabonomic or diagnostic purposes, new challenges have arisen concerning the efficacy of NMR data acquisition and analysis. In particular the quantification of sample constituents such as metabolites is of great importance. This study compares five one-dimensional proton NMR pulse sequences using synthetic urine samples to determine appropriate acquisition parameters for reasonable sample throughput and accuracy. Each pulse sequence has its own advantages and limitations with respect to solvent suppression, stable baseline, exchangeable protons, and quantization of resonances near the residual water peak. Hardware issues such as low-pass filters, unique to each spectrometer, also impact quantitation accuracy. Metabolite concentrations were determined using integration referenced to an added internal standard, and using the Chenomx NMR Suite software package. Since nuclei in different metabolites and the internal standard all have different longitudinal relaxation rates (T1) we included a mathematical correction factor for quantitation.
引用
收藏
页码:113 / 123
页数:10
相关论文
共 63 条
[1]  
Brindle J.T.(2002)Rapid and noninvasive diagnosis of the presence and severity of coronary heart disease using 1H-NMR-based metabonomics Nat. Med. 8 1439-1444
[2]  
Antti H.(2002)Accurate nucleic acid concentrations by nuclear magnetic resonance Anal. Biochem. 308 373-380
[3]  
Holmes E.(2005)Proton nuclear magnetic resonance-based metabonomics for rapid diagnosis of meningitis and ventriculitis Clin. Infect. Dis. 41 1582-90
[4]  
Cavaluzzi M.J.(2005)Curve-fitting method for direct quantitation of compounds in complex biological mixtures using 1H NMR: application in metabonomic toxicology studies Anal. Chem. 77 4556-4562
[5]  
Kerwood D.J.(2003)Quantitative 1H NMR spectroscopy of blood plasma metabolites Anal. Chem. 75 2100-2104
[6]  
Borer P.N.(1998)Assay by nuclear magnetic resonance spectroscopy:quantification limits Analyst 123 1061-1068
[7]  
Coen M.(1983)Solvent Suppression in Fourier Transform Nuclear Magnetic Resonance J. Magn. Reson. 55 283-300
[8]  
O’Sullivan M.(1976)Solvent peak saturation with single phase and quadrature Fourier transformation J. Magn. Reson. 21 337-347
[9]  
Bubb W.A.(1995)Water Suppression That Works. Excitation Sculpting using Arbitrary Waveforms and Pulsed Field Gradients J. Magn. Reson. 112 275-279
[10]  
Kuchel P.W.(2005)Characterization and optimization of experimental variables within a reproducible bladder encrustation model and in vitro evaluation of the efficacy of urease inhibitors for the prevention of medical device-related encrustation J. Biomed. Mat. Res. Part B: Appl. Biomater. 76 1-7