Automated Determination of Cd2+ and Pb2+ in Natural Waters with Sequential Injection Analysis Device Using Differential Pulse Anodic Stripping Voltammetry

被引:0
作者
Zhiwei Lai
Fangyuan Lin
Yipeng Huang
Yiru Wang
Xi Chen
机构
[1] Xiamen University,MOE Key Laboratory of Spectrochemical Analysis and Instrumentation, College of Chemistry and Chemical Engineering
[2] Xiamen University,State Key Laboratory of Marine Environmental Science
来源
Journal of Analysis and Testing | 2021年 / 5卷
关键词
Electrochemical flow device; Differential pulse anodic stripping voltammetry; Cd; Pb; Water samples;
D O I
暂无
中图分类号
学科分类号
摘要
An electrochemical flow device has been developed for the determination of heavy metal ions (HMI) in water using multi-walled carbon nanotubes (MWCNTs)/Nafion(NA)/Hg electrode, by mean of differential pulse anodic stripping voltammetry coupled with sequential injection analysis. The accuracy of the determination was ensured by the great electrical conductivity of MWCNTs and the high adsorption capacity of Hg. NA was used for MWCNTs immobilization for the long-term application of the electrode. The mercury film was cleaned after determination and another one would form during deposition. A lower limit of detection and a wider determination range of Cd2+ and Pb2+ could be achieved using the automatically analytical device combining with the MWCNTs/NA/Hg-modified electrode. The real-time monitoring of Cd2+ and Pb2+ in fresh water using this device continued for 10 days. The results indicated that the method was potential for on-site and real-time determination of HMI in water samples.
引用
收藏
页码:60 / 68
页数:8
相关论文
共 175 条
  • [1] Kava AA(2020)Disposable glassy carbon stencil printed electrodes for trace detection of cadmium and lead Anal Chim Acta. 1103 58-66
  • [2] Beardsley C(2016)Urinary cadmium and mortality from all causes, cancer and cardiovascular disease in the general population: systematic review and meta-analysis of cohort studies Int J Epidemiol. 45 782-791
  • [3] Hofstetter J(2018)3D-printed lab-on-valve for fluorescent determination of cadmium and lead in water Talanta 183 201-208
  • [4] Henry CS(2020)Highly sensitive detection of Pb Anal Chim Acta. 1124 166-175
  • [5] Larsson SC(2020) and Cu Sens Actuators B Chem. 310 127756-127768
  • [6] Wolk A(2014) based on ZIF-67/MWCNT/Nafion-modified glassy carbon electrode Electroanalysis 26 2754-2763
  • [7] Mattio E(2014)A ratiometric electrochemical sensor for simultaneous detection of multiple heavy metal ions based on ferrocene-functionalized metal-organic framework Talanta 126 82-90
  • [8] Robert-Peillard F(2012)Automated determination of Cu(II), Pb(II), Cd(II) and Zn(II) in environmental samples by square wave voltammetry exploiting sequential injection analysis and screen printed electrodes Talanta 96 75-81
  • [9] Vassalo L(2010)A thermostated electrochemical flow cell with a coupled bismuth film electrode for square-wave anodic stripping voltammetric determination of cadmium(II) and lead(II) in natural, wastewater and tap water samples Anal Chim Acta. 668 54-60
  • [10] Branger C(2017)On-line preconcentration and determination of lead and cadmium by sequential injection/anodic stripping voltammetry Microchem J. 130 157-161