Contrast-enhanced spectral mammography: Does mammography provide additional clinical benefits or can some radiation exposure be avoided?

被引:0
作者
Eva Maria Fallenberg
Clarisse Dromain
Felix Diekmann
Diane M. Renz
Heba Amer
Barbara Ingold-Heppner
Avidan U. Neumann
Klaus J. Winzer
Ulrich Bick
Bernd Hamm
Florian Engelken
机构
[1] Charité - Universitätsmedizin Berlin,Clinic of Radiology
[2] Institut Gustave Roussy,Department of Radiology
[3] St. Joseph-Stift Bremen,Department of Medical Imaging
[4] Charité - Universitätsmedizin Berlin,Institute of Pathology
[5] Charité - Universitätsmedizin Berlin,Interdisciplinary Breast Center, Department of Gynecology
[6] Bar-Ilan University,Goodman Faculty of Life Sciences
[7] Charité - Universitätsmedizin Berlin,Department of Radiology
[8] Charité - Universitätsmedizin Berlin,Clinic of Radiology
来源
Breast Cancer Research and Treatment | 2014年 / 146卷
关键词
Breast cancer; Detection; Contrast-enhanced spectral mammography; Dual-energy; Contrast media; Radiation exposure; Sensitivity; Digital mammography;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to compare contrast-enhanced spectral mammography (CESM) with mammography (MG) and combined CESM + MG in terms of detection and size estimation of histologically proven breast cancers in order to assess the potential to reduce radiation exposure. A total of 118 patients underwent MG and CESM and had final histological results. CESM was performed as a bilateral examination starting 2 min after injection of iodinated contrast medium. Three independent blinded radiologists read the CESM, MG, and CESM + MG images with an interval of at least 4 weeks to avoid case memorization. Sensitivity and size measurement correlation and differences were calculated, average glandular dose (AGD) levels were compared, and breast densities were reported. Fisher’s exact and Wilcoxon tests were performed. A total of 107 imaging pairs were available for analysis. Densities were ACR1: 2, ACR2: 45, ACR3: 42, and ACR4: 18. Mean AGD was 1.89 mGy for CESM alone, 1.78 mGy for MG, and 3.67 mGy for the combination. In very dense breasts, AGD of CESM was significantly lower than MG. Sensitivity across readers was 77.9 % for MG alone, 94.7 % for CESM, and 95 % for CESM + MG. Average tumor size measurement error compared to postsurgical pathology was −0.6 mm for MG, +0.6 mm for CESM, and +4.5 mm for CESM + MG (p < 0.001 for CESM + MG vs. both modalities). CESM alone has the same sensitivity and better size assessment as CESM + MG and was significantly better than MG with only 6.2 % increase in AGD. The combination of CESM + MG led to systematic size overestimation. When a CESM examination is planned, additional MG can be avoided, with the possibility of saving up to 61 % of radiation dose, especially in patients with dense breasts.
引用
收藏
页码:371 / 381
页数:10
相关论文
共 169 条
  • [1] Kolb TM(2002)Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations Radiology 225 165-175
  • [2] Lichy J(2005)Diagnostic performance of digital versus film mammography for breast-cancer screening N Engl J Med 353 1773-1783
  • [3] Newhouse JH(2011)Swedish two-county trial: impact of mammographic screening on breast cancer mortality during 3 decades Radiology 260 658-663
  • [4] Pisano ED(2012)Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996–2010 J Am Med Assoc 307 2400-2409
  • [5] Gatsonis C(2010)Cancer report examines environmental hazards Environ Health Perspect 118 a336-a61
  • [6] Hendrick E(2012)IOM issues report on breast cancer and the environment Environ Health Perspect 120 a60-298
  • [7] Yaffe M(2013)ALARA and digital imaging systems Radiol Technol 84 297-362
  • [8] Baum JK(2011)White paper on radiation protection by the European Society of Radiology Insights Imaging 2 357-904
  • [9] Acharyya S(2012)Dose reduction and adequate image quality in digital radiography: a contradiction? Der Radiol 52 898-490
  • [10] Conant EF(2013)ALARA in existing exposure situations: 14th European ALARA network workshop, 4–6 September 2012, Dublin J Radiol Prot Off J Soc Radiol Prot 33 487-574