Impacts of fouling and cleaning on the performance of plate fin and spine fin heat exchangers

被引:0
作者
Bock Choon Pak
Byung Joon Baek
Eckhard A. Groll
机构
[1] Chonbuk National University,Division of Mechanical and Aerospace System Engineering
[2] Purdue University,School of Mechanical Engineering
来源
KSME International Journal | 2003年 / 17卷
关键词
Air-side Fouling; Condenser; Cleaning; Pressure Drop; Heat Transfer Performance;
D O I
暂无
中图分类号
学科分类号
摘要
An experimental study was conducted to investigate the effects of air-side fouling and cleaning on the performances of various condenser coils used in unitary air-conditioning systems. A total of six condenser coils with different fin geometry and row number were tested. Performance tests were performed at three different conditions: clean-as-received, after fouling, and after cleaning. In all cases, it was observed that the fouling was mostly confined to the frontal face of the heat exchanger as reported in the previous investigations. The amount of deposited dust was more dependent on fin geometry for the single-row heat exchangers than for the double-row heat exchangers. The predominant effect of fouling was to cause a more significant increase in air-side pressure drop than a degradation in heat transfer performance. For the single-row heat exchangers, the pressure drop increased by 28 to 31%, while the heat transfer performance decreased by 7 to 12% at the standard air face velocity of 1.53 m/s depending on fin shape. For the double-row heat exchangers, the pressure drop increased by 22 to 37%, and heat transfer performance decreased by only 4-5% at the same air face velocity. Once the contaminated coils were cleaned according to the given cleaning procedure the original performance of the heat exchangers could almost be recovered completely. The pressure drop could be restored within 1 to 7% and the heat transfer performance could be recovered to within 1 to 5% of the originally clean heat exchangers. Therefore, it is concluded that a periodic application of the specified cleaning technique will be effective in maintaining the thermal performance of the condenser coils.
引用
收藏
页码:1801 / 1811
页数:10
相关论文
共 18 条
[1]  
Bott. T. R.(1983)Particulate Fouling on the Gas-side of Finned Tube Heat Exchangers J. of Heat Transfer, ASME 105 178-183
[2]  
Bemrose C. R.(1998)Common Faults and Their Impacts for Rooftop air Conditioners International Journal of Heating, Ventilating, Air-Conditioning and Refrigerating Research 4 303-318
[3]  
Breuker M. S.(1981)Air-side Fouling of Internal Combustion Engine Radiators SAE Trans. 89 3179-3188
[4]  
Braun J. E.(1990)Progress in Gas-side Fouling of Heat-transfer Surfaces Applied Mechanics Review 43 35-66
[5]  
Cowell T.(1977)The History and Status of Research in Fouling of Heat Exchangers in Cooling Water Service The Canadian J. of Chem. Eng. 55 374-380
[6]  
Cross D. A.(1972)Fouling : The Major Unsolved Problem in Heat Transfer Chermical Engineering Engineering Progress 68 59-67
[7]  
Marner. W.(1990)Finned Tube Heat Exchanger Fouling by Particles Proc. of the 9th Int. Heat Transfer Conf 5 115-120
[8]  
Suitor J. W.(undefined)undefined undefined undefined undefined-undefined
[9]  
Marner W. J.(undefined)undefined undefined undefined undefined-undefined
[10]  
Ritter. R. B.(undefined)undefined undefined undefined undefined-undefined