Sensitivity of MEG and EEG to Source Orientation

被引:0
作者
Seppo P. Ahlfors
Jooman Han
John W. Belliveau
Matti S. Hämäläinen
机构
[1] MGH/HST Athinoula A. Martinos Center for Biomedical Imaging,
[2] Massachusetts General Hospital/Harvard Medical School,undefined
[3] Harvard-MIT Division of Health Sciences and Technology,undefined
来源
Brain Topography | 2010年 / 23卷
关键词
Magnetoencephalography; Electroencephalography; Suppression ratio; Current dipole; Radial source current;
D O I
暂无
中图分类号
学科分类号
摘要
An important difference between magnetoencephalography (MEG) and electroencephalography (EEG) is that MEG is insensitive to radially oriented sources. We quantified computationally the dependency of MEG and EEG on the source orientation using a forward model with realistic tissue boundaries. Similar to the simpler case of a spherical head model, in which MEG cannot see radial sources at all, for most cortical locations there was a source orientation to which MEG was insensitive. The median value for the ratio of the signal magnitude for the source orientation of the lowest and the highest sensitivity was 0.06 for MEG and 0.63 for EEG. The difference in the sensitivity to the source orientation is expected to contribute to systematic differences in the signal-to-noise ratio between MEG and EEG.
引用
收藏
页码:227 / 232
页数:5
相关论文
共 167 条
  • [1] Ahlfors SP(2010)Cancellation of EEG and MEG signals generated by extended and distributed sources Hum Brain Mapp 31 140-149
  • [2] Han J(2001)Electromagnetic brain mapping IEEE Signal Proc Mag 18 14-30
  • [3] Lin FH(1965)Theory of magnetic detection of the heart’s electrical activity J Appl Phys 36 2066-2073
  • [4] Witzel T(1983)Demonstration of useful differences between magnetoencephalogram and electroencephalogram Electroencephalogr Clin Neurophysiol 56 38-51
  • [5] Belliveau JW(1991)EEG versus MEG localization accuracy: theory and experiment Brain Topogr 4 95-103
  • [6] Hämäläinen MS(1990)Effects of head shape on EEG’s and MEG’s IEEE Trans Biomed Eng 37 44-52
  • [7] Halgren E(1999)Cortical surface-based analysis. I. Segmentation and surface reconstruction NeuroImage 9 179-194
  • [8] Baillet S(2005)Differences in MEG/EEG epileptic spike yields explained by regional differences in signal-to-noise ratios J Clin Neurophysiol 22 153-158
  • [9] Mosher JC(1997)Differential outcomes from magneto- and electroencephalography for the analysis of human cognition Neurosci Lett 227 185-188
  • [10] Leahy RM(1999)Cortical surface-based analysis. II: Inflation, flattening, and a surface-based coordinate system NeuroImage 9 195-207