Certification of reference materials for the quality control of major element determinations in groundwater Part 2: CertificationPart 2: Certification

被引:0
|
作者
P. Quevauviller
M. J. Benoliel
R. Neves Carneiro
L. Cortez
机构
[1] European Commission,
[2] Standards,undefined
[3] Measurements and Testing Programme,undefined
[4] Rue de la Loi 200,undefined
[5] B-1049 Brussels,undefined
[6] Belgium,undefined
[7] Empresa Portuguesa das Águas Livres,undefined
[8] Divisão de Laboratorios,undefined
[9] 12,undefined
[10] Rua de Alviela,undefined
[11] P-1170 Lisboa,undefined
[12] Portugal,undefined
[13] Instituto Português de Qualidade,undefined
[14] Avenida dos Três Vales,undefined
[15] P-2825 Monte da Caparica,undefined
[16] Portugal,undefined
来源
Fresenius' Journal of Analytical Chemistry | 1999年 / 363卷
关键词
Quality Control; Carbonate Content; Reference Material; Major Element; High Carbonate;
D O I
暂无
中图分类号
学科分类号
摘要
The quality control of groundwater monitoring requires the availability of representative CRMs. This paper describes the preparation of two artificial groundwater reference materials, CRM 616 (high carbonate content) and CRM 617 (low carbonate content), the homogeneity and stability studies and the analytical work performed for the certification of a range of major elements (Ca, Cl, Fe, K, Mg, Mn, Na, NO3, PO4 and SO4).
引用
收藏
页码:23 / 27
页数:4
相关论文
共 36 条
  • [31] Comparison of the types of candidate reference samples for quality control of human epidermal growth factor receptor 2 status detection
    Yulong Li
    Rui Zhang
    Yanxi Han
    Tian Lu
    Jiansheng Ding
    Kuo Zhang
    Guigao Lin
    Jiehong Xie
    Jinming Li
    Diagnostic Pathology, 11
  • [32] Automated quality control tool for high-content imaging data by building 2D prediction intervals on reference biosignatures
    Assefa, Alemu Takele
    Verbist, Bie
    Gustin, Emmanuel
    Peeters, Danielle
    SLAS DISCOVERY, 2023, 28 (03) : 111 - 117
  • [33] Platinum-Group Element Results for Two Cobalt-Rich Seamount Crust Ultra-Fine Reference Materials: MCPt-1 and MCPt-2
    Wang, Yimin
    Wang, Xiaohong
    Qu, Wenjun
    Gao, Yushu
    Gu, Tiexin
    Fan, Xingtao
    Andreev, S. I.
    Shi, Xuefa
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2011, 35 (03) : 341 - 352
  • [34] CANDIDATE REFERENCE METHODS FOR DETERMINING TARGET VALUES FOR CHOLESTEROL, CREATININE, URIC-ACID, AND GLUCOSE IN EXTERNAL QUALITY ASSESSMENT AND INTERNAL ACCURACY CONTROL .2. METHOD TRANSFER
    THIENPONT, LM
    DELEENHEER, AP
    STOCKL, D
    REINAUER, H
    CLINICAL CHEMISTRY, 1993, 39 (06) : 1001 - 1006
  • [35] Quality control charts for short or long runs without a training phase. Part 2. Performances in the presence of a persistent systematic error and simultaneous small shifts in the mean and the variance
    Alvarez-Prieto, Manuel
    Paez-Montero, Ricardo
    ACCREDITATION AND QUALITY ASSURANCE, 2025, 30 (01) : 35 - 44
  • [36] Qualification and quality control in forensic psychiatry: The current situation in Switzerland: Part 2: Civil and social law; [Qualifizierung und Qualitätskontrolle in der forensischen Psychiatrie - die aktuelle Situation in der Schweiz: Teil 2: Zivil- und Sozialrecht]
    Sachs J.
    Habermeyer E.
    Ebner G.
    Forensische Psychiatrie, Psychologie, Kriminologie, 2014, 8 (1) : 34 - 40