Undersampling patterns in k-space for compressed sensing MRI using two-dimensional Cartesian sampling

被引:12
作者
Kojima S. [1 ]
Shinohara H. [2 ]
Hashimoto T. [3 ]
Suzuki S. [1 ]
机构
[1] Department of Radiology, Tokyo Women’s Medical University Medical Center East, 2-1-10 Arakawa-ku, Tokyo
[2] Tokyo Metropolitan University, 7-2-10 Arakawa-ku, Tokyo
[3] Department of Medical Radiological Technology, Faculty of Health Sciences, Kyorin University, 5-4-1 Shimorenjaku, Mitaka-shi, Tokyo
关键词
2D Cartesian sampling; Brain; Compressed sensing MRI; Image reconstruction; k-Space; Undersampling pattern;
D O I
10.1007/s12194-018-0469-y
中图分类号
学科分类号
摘要
In compressed sensing magnetic resonance imaging (CS-MRI), undersampling of k-space is performed to achieve faster imaging. For this process, it is important to acquire data randomly, and an optimal random undersampling pattern is required. However, random undersampling is difficult in two-dimensional (2D) Cartesian sampling. In this study, the effect of random undersampling patterns on image reconstruction was clarified using phantom and in vivo MRI, and a sampling pattern relevant for 2D Cartesian sampling in CS-MRI is suggested. The precision of image restoration was estimated with various acceleration factors and extents for the fully sampled central region of k-space. The root-mean-square error, structural similarity index, and modulation transfer function were measured, and visual assessments were also performed. The undersampling pattern was shown to influence the precision of image restoration, and an optimal undersampling pattern should be used to improve image quality; therefore, we suggest that the ideal undersampling pattern in CS-MRI for 2D Cartesian sampling is one with a high extent for the fully sampled central region of k-space. © 2018, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:303 / 319
页数:16
相关论文
共 20 条
[1]  
Mann L.W., Higgins D.M., Peters C.N., Cassidy S., Hodson K.K., Coombs A., Taylor R., Hollingsworth K.G., Accelerating MR imaging liver steatosis measurement using combined compressed sensing and parallel imaging: a quantitative evaluation, Radiology, 278, 1, pp. 247-256, (2016)
[2]  
Li B., Li H., Kong H., Dong L., Zhang J., Fang J., Compressed sensing based simultaneous black- and gray-blood carotid vessel wall MR imaging, Magn Reson Imaging, 38, pp. 214-223, (2017)
[3]  
Kido T., Kido T., Nakamura M., Watanabe K., Schmidt M., Forman C., Mochizuki T., Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold, J Cardiovasc Magn Reson, 18, 1, (2016)
[4]  
Han S., Cho H., Temporal resolution improvement of calibration-free dynamic contrast-enhanced MRI with compressed sensing optimized turbo spin echo: the effects of replacing turbo factor with compressed sensing accelerations, J Magn Reson Imaging, 44, 1, pp. 138-147, (2016)
[5]  
Kim S.G., Feng L., Grimm R., Freed M., Block K.T., Sodickson D.K., Moy L., Otazo R., Influence of temporal regularization and radial undersampling factor on compressed sensing reconstruction in dynamic contrast enhanced MRI of the breast, J Magn Reson Imaging, 43, 1, pp. 261-269, (2016)
[6]  
Nam S., Hong S.N., Akcakaya M., Kwak Y., Goddu B., Kissinger K.V., Manning W.J., Tarokh V., Nezafat R., Compressed sensing reconstruction for undersampled breath-hold radial cine imaging with auxiliary free-breathing data, J Magn Reson Imaging, 39, 1, pp. 179-188, (2014)
[7]  
Rapacchi S., Han F., Natsuaki Y., Kroeker R., Plotnik A., Lehrman E., Sayre J., Laub G., Finn J.P., Hu P., High spatial and temporal resolution dynamic contrast-enhanced magnetic resonance angiography using compressed sensing with magnitude image subtraction, Magn Reson Med, 71, 5, pp. 1771-1783, (2014)
[8]  
Wang H., Miao Y., Zhou K., Yu Y., Bao S., He Q., Dai Y., Xuan S.Y., Tarabishy B., Ye Y., Hu J., Feasibility of high temporal resolution breast DCE-MRI using compressed sensing theory, Med Phys, 37, 9, pp. 4971-4981, (2010)
[9]  
Smith D.S., Welch E.B., Li X., Arlinghaus L.R., Loveless M.E., Koyama T., Gore J.C., Yankeelov T.E., Quantitative effects of using compressed sensing in dynamic contrast enhanced MRI, Phys Med Biol, 56, 15, pp. 4933-4946, (2011)
[10]  
Worters P.W., Sung K., Stevens K.J., Koch K.M., Hargreaves B.A., Compressed-sensing multispectral imaging of the postoperative spine, J Magn Reson Imaging, 37, 1, pp. 243-248, (2013)