CT-guided percutaneous transthoracic biopsy in the diagnosis of mediastinal masses: Evaluation of 73 procedures

被引:48
作者
Priola A.M. [1 ]
Priola S.M. [1 ]
Cataldi A. [1 ]
Ferrero B. [2 ]
Garofalo G. [1 ]
Errico L. [3 ]
Marci V. [4 ]
Fava C. [1 ]
机构
[1] Radiologia Diagnostica, Dipartimento di Scienze Cliniche e Biologiche, A.S.O. San Luigi Gonzaga
[2] Neurologia, Dipartimento di Scienze Cliniche e Biologiche, A.S.O. San Luigi Gonzaga
[3] Chirurgia Toracica, Dipartimento di Scienze Cliniche e Biologiche, A.S.O. San Luigi Gonzaga
[4] Anatomia Patologica, Dipartimento di Scienze Cliniche e Biologiche, A.S.O. San Luigi Gonzaga, Orbassano (TO) 10043
关键词
Biopsy; Complications; Computed tomography (CT); Diagnostic accuracy; Guidance; Mediastinum;
D O I
10.1007/s11547-008-0233-1
中图分类号
学科分类号
摘要
Purpose. This study was performed to evaluate the factors affecting the diagnostic accuracy and rate of complications of CT-guided percutaneous transthoracic needle biopsy of mediastinal masses. Materials and methods. We reviewed 73 consecutive mediastinal biopsies in 70 patients. Final diagnoses were based on a retrospective analysis of surgical outcomes, results of repeat biopsies or findings of imaging and clinical follow-up lasting at least 4 months. Benign and malignant biopsy findings were compared with the final outcomes to determine the diagnostic accuracy of the method. Finally, we analysed the complications. Results. CT-guided percutaneous transthoracic needle biopsy provided adequate samples in 61/73 cases, with a total sample rate of 83.6%. Of these 61 biopsies, 51 yielded a correct diagnosis with specific histological typing, mainly in the case of thymoma and metastasis. Lymphomas were less reliably diagnosed. The overall sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy values were 83.6%, 100%, 100%, 35.3% and 83.6%, respectively. Pneumothorax was the most common complication (5.5%). Conclusions. CT-guided percutaneous transthoracic needle biopsy is an easy, reliable and safe procedure that obviates the need for exploratory surgery in medically treatable or unresectable cases. It should be the first invasive procedure in the diagnostic workup of mediastinal masses. © 2008 Springer-Verlag.
引用
收藏
页码:3 / 15
页数:12
相关论文
共 20 条
  • [1] Priola A.M., Priola S.M., Cardinale L., Et al., The anterior mediastinum: Diseases (Il mediastino anteriore: Patologie), Radiol Med, 11, pp. 312-342, (2006)
  • [2] Priola S.M., Priola A.M., Cardinale L., Et al., The anterior mediastinum: Anatomy and imaging procedures (Il mediastino anteriore: Anatomia e tecniche di studio), Radiol Med, 11, pp. 295-311, (2006)
  • [3] Adler O.B., Rosenberg A., Peleg H., Fine-needle aspiration biopsy of mediastinal masses: Evaluation of 136 experiences, AJR Am J Roentgenol, 140, pp. 893-896, (1983)
  • [4] Weisbrod G.L., Lyons D.J., Tao L.C., Et al., Percutaneous fine-needle aspiration biopsy of mediastinal lesions, AJR Am J Roentgenol, 143, pp. 525-529, (1984)
  • [5] Herman S.J., Holub R.V., Weisbrod G.L., Et al., Anterior mediastinal masses: Utility of transthoracic needle biopsy, Radiology, 180, pp. 167-170, (1991)
  • [6] Protopapas Z., Westcott J.L., Transthoracic hilar and mediastinal biopsy, Radiol Clin North Am, 38, pp. 281-291, (2000)
  • [7] Gupta S., Seaberg K., Wallace M.J., Et al., Imaging-guided percutaneous biopsy of mediastinal lesions: Different approaches and anatomic considerations, Radiographics, 25, pp. 786-788, (2005)
  • [8] Silverman S.G., Lee B.Y., Mueller P.R., Et al., Impact of positive findings at image-guided biopsy of lymphoma on patient care: Evaluation of clinical history, needle size, and pathologic findings on biopsy performance, Radiology, 190, pp. 759-764, (1994)
  • [9] Ben-Yehuda D., Polliack A., Okon E., Et al., Image-guided core-needle biopsy in malignant lymphoma: Experience with 100 patients that suggests the technique is reliable, J Clin Oncol, 14, pp. 2431-2434, (1996)
  • [10] Klein J.S., Salomon G., Stewart E.A., Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients, Radiolog, 198, pp. 715-720, (1996)