Comparison of different carbon ink based screen-printed electrodes towards amperometric immunosensing

被引:0
作者
V. K. Rao
M. K. Sharma
P. Pandey
K. Sekhar
机构
[1] Defence Research & Development Establishment,P.D.Division
来源
World Journal of Microbiology and Biotechnology | 2006年 / 22卷
关键词
Screen-printed electrodes; Immunosensors; Carbon inks; Mouse IgG; Amperometry; ELISA;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of the present work was to make amperometric immunosensors based on the principle of enzyme-linked immunosorbent assay (ELISA). For this purpose, screen-printed electrodes (SPEs) were fabricated using various carbon inks (commercially available inks Gwent, Acheson, Eltecks and two homemade inks PSG & PVCG) to determine the best ink in realizing immunosensors. Amperometric immunosensors made by different carbon inks were compared with standard ELISA in terms of total assay time, amount of biological materials used and sensitivity of detection. A model system containing rabbit anti-mouse immunoglobulin G (RαMIgG) as the capturing antibody, mouse IgG (MIgG) as antigen and alkaline phosphatase conjugated RαMIgG as revealing antibody was used. In these studies, 1-naphthyl phosphate was used as substrate. The experiments done include electrochemical characterization of electrodes, optimization of dilutions of antibodies, immobilization of antibody on the electrode were carried out. The minimum detection limit for the best results of MIgG determination were obtained on screen-printed electrode made by Gwent carbon ink and PSG carbon ink, with a detection limit of 1.0 and 2.0 ng/ml respectively. The time required for detection of mouse IgG was 40 min for SPEs. By using the conventional spectrophotometric method (ELISA method), the minimum detection limit for the MIgG (antigen) detection was 50 ng/ml and the time required for analysis was found to be 140 min.
引用
收藏
页码:1135 / 1143
页数:8
相关论文
共 117 条
[1]  
Alvaraz-Icaza M(1993)Mass production of biosensors Anal Chem 65 525A-533A
[2]  
Bilitewski U(1997)Subfemtomolar determination of alkaline phosphatase at a disposable screen-printed electrodes modified with a perfluorosulfonated inomer film Anal Chem 69 4688-4694
[3]  
Bagel O(1996)Immunoelectrochemical assay for bacteria: use of epifluorescence Microscopy and rapid scan electrochemical techniques in development of assay for Anal Chem 68 4153-4159
[4]  
Limoges B(1993)Screen-printed glucose electrodes based on platinised carbon particles and glucose oxidase Anal Chim Acta 276 69-74
[5]  
Schollhorn B(2004)Screening of food samples for carbamates and organophosphates using an electrochemical bioassay Food Chem 84 651-656
[6]  
Degard C(1999)An indirect perfluorosulphonated ionomer-coated electrochemical immunosensor for the detection of the protein human chorionic gonadotropin Anal Chem 71 4088-4094
[7]  
Brewster D(2001)Effect of pre-treatment on the surface and electrochemical properties of screen-printed carbon paste electrodes Analyst 126 1399-1403
[8]  
Gehring AG(1999)Increasing sensitivity of Analyst 124 295-299
[9]  
Mazenko RS(1997) assays: evaluation using ELISA and amperometric detection Biosen Bioelectron 12 403-413
[10]  
Houten LJV(1995)Adsorption of immunoglobulin G on carbon paste electrode as a basis for the development of immunoelectrochemical devices Trends Anal Chem 14 225-231