Evaluation of Xpert MTB/RIF Ultra performance for pulmonary tuberculosis diagnosis on smear-negative respiratory samples in a French centre

被引:0
作者
Elisabeth Hodille
Audey Maisson
Laurine Charlet
Clyde Bauduin
Charlotte Genestet
Isabelle Fredenucci
Jean-Philippe Rasigade
Gérard Lina
Oana Dumitrescu
机构
[1] Hôpital de la Croix Rousse-Centre de Biologie Nord,Hospices Civils de Lyon
[2] Institut des Agents Infectieux,Centre International de Recherche en Infectiologie, INSERM U1111
[3] Laboratoire de Bactériologie,undefined
[4] Université de Lyon,undefined
来源
European Journal of Clinical Microbiology & Infectious Diseases | 2019年 / 38卷
关键词
Xpert MTB/RIF Ultra; Pulmonary tuberculosis; Diagnosis; High-resource setting; Smear-negative;
D O I
暂无
中图分类号
学科分类号
摘要
Tuberculosis (TB) is a worldwide public health concern, including in high-resource countries with a low prevalence of TB. Xpert MTB/RIF assay was developed to improve TB and rifampicin (RIF) resistance detection, but sensitivity remains poor on smear-negative sputum. Xpert MTB/RIF Ultra assay was designed to enhance the sensitivity of TB detection in clinical samples. Herein, we evaluated retrospectively the performance of this test on smear-negative respiratory samples. Respiratory specimens with smear-negative and a Mycobacterium tuberculosis (MTB) complex-positive culture were retrospectively selected from those taken from patients during routine care, and analysed in the Mycobacteria Laboratory of the Lyon University hospital, France. Specimens were stored at − 20 °C before testing by Xpert MTB/RIF Ultra. For each sample, growth delay and date of anti-TB treatment initiation were recorded. Forty-six samples—29 sputum, 8 bronchial aspirates, 6 broncho-alveolar lavages, and 3 gastric aspirates—were selected. Among samples collected before treatment initiation (n = 33), sensitivity was 81.8% (95% CI [64.5; 93.0]) and there was a significant correlation between the quantitative measurements (Ct) of Xpert MTB/RIF Ultra assay and the time to growth detection in culture. Among samples collected after treatment initiation (n = 12), sensitivity was 100%, without correlation with time to growth detection due to presence of afterglow DNA in samples. In high-resource settings, the Xpert MTB/RIF Ultra test represents a useful tool for pulmonary TB diagnosis, notably for the paucibacillary forms. Moreover, quantitative measurement of Xpert MTB/RIF Ultra could help to predict time to MTB culture positivity and be used as a quality indicator of MTB culture process.
引用
收藏
页码:601 / 605
页数:4
相关论文
共 61 条
[1]  
Sohn H(2009)Updated guidelines for the use of nucleic acid amplification tests in the diagnosis of tuberculosis MMWR Morb Mortal Wkly Rep 58 7-10
[2]  
Aero AD(2014)Xpert MTB/RIF testing in a low tuberculosis incidence, high-resource setting: limitations in accuracy and clinical impact Clin Infect Dis 58 970-976
[3]  
Menzies D(2014)Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults Cochrane Database Syst Rev 21 CD009593-131
[4]  
Behr M(2017)Diagnostic usefulness of Xpert MTB/RIF assay for detection of tuberculous meningitis using cerebrospinal fluid J Inf Secur 75 125-75
[5]  
Schwartzman K(2017)The new Xpert MTB/RIF Ultra: improving detection of Mycobacterium tuberculosis and resistance to rifampin in an assay suitable for point-of-care testing mBio 29 8-84
[6]  
Alvarez GG(2017)Diagnostic accuracy of Xpert MTB/RIF Ultra for tuberculous meningitis in HIV-infected adults: a prospective cohort study Lancet Infect Dis 18 68-1432
[7]  
Steingart KR(2018)Xpert MTB/RIF Ultra for detection of Mycobacterium tuberculosis and rifampicin resistance: a prospective multicentre diagnostic accuracy study Lancet Infect Dis 18 76-2764
[8]  
Schiller I(2018)Improvement of Mycobacterium tuberculosis detection by Xpert MTB/RIF Ultra: a head-to-head comparison on Xpert-negative samples PLoS One 13 e0201934-367
[9]  
Horne DJ(1987)Simplified acetylcysteine-alkali digestion-decontamination procedure for isolation of mycobacteria from clinical specimens J Clin Microbiol 25 1428-10
[10]  
Pai M(1995)Phenolic acridine orange fluorescent stain for mycobacteria J Clin Microbiol 33 2763-undefined