Experimental and Theoretical Analysis of Connector Offset Optical Fiber Refractive Index Sensor

被引:0
作者
Vanita Bhardwaj
Kamal Kishor
Vinod Kumar Singh
机构
[1] Indian Institute of Technology (Indian School of Mines),Department of Applied Physics
[2] Delhi Technological University (Formerly Delhi College of Engineering),TIFAC
来源
Plasmonics | 2017年 / 12卷
关键词
No core fiber; Core-offset; Mach-Zehnder interferometer; Refractive index;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, a high sensitive connector offset optical fiber sensor is employed to detect the refractive index of liquid. The configuration chosen for this experiment is formed by lateral core offset fusion splicing of no-core fiber (NCF) between the single mode fibers (SMF) and cladding modes are excited by misalignment. The sensing principle for refractive index detection is based on Mach-Zehnder Interferometer (MZI) principle and the experiment is carried out by immersion of device in NaCl solutions of different refractive indices. Such refractive index sensor exhibits high sensitivity 197.33 nm/RIU for the surrounding refractive index variation from 1.333 to 1.380, and the result shows the excellent agreement with theoretical analysis. Compared to other sensors, the proposed device has the potential to provide high sensitivity, ease of fabrication, low cost, compact size, and linear response. Thus, it can be used in many applications such as bio-sensors, chemical sensor, temperature sensor, and pressure sensor.
引用
收藏
页码:1999 / 2004
页数:5
相关论文
共 83 条
[1]  
Wang Q(2016)Optimization of cascaded fiber tapered Mach-Zehnder interferometer and refractive index sensing technology Sens. and Actuator B: Chem. 222 159-165
[2]  
Wei W(2011)In fiber Mach-Zehnder interferometer based double cladding fibers for refractive index sensor IEEE Sensors J 11 2395-2400
[3]  
Guo M(2016)Fabrication and characterization of cascaded tapered Mach-Zehnder interferometer for refractive index sensing Sens and Actuator A: Phy 244 30-40
[4]  
Zhao Y(2016)Polarization-dependent humidity sensor based on an in-fiber Mach-Zehnder interferometer coated with grapheme oxide Sens and Actuator B: Chem 234 503-509
[5]  
Pang F(2016)Switchable and multi-wavelength linear fiber laser based on Fabry-Perot and Mach-Zehnder interferometer Opt Commun 374 39-44
[6]  
Liu H(2016)Intensity-modulated abrupt tapered fiber Mach-Zehnder interferometer for the simultaneous sensing of temperature and curvature Opt. & Laser Techn. 86 8-13
[7]  
Guo H(2004)Measurements of refractive index sensitivity using long-period grating refractometer Opt Commun 229 65-69
[8]  
Bhardwaj V(2005)Highly sensitive fiber Bragg grating refractive index sensor Appl Phys Lett 86 151122-395
[9]  
Singh VK(2015)A novel graphene based tapered optical fiber sensor for glucose detection Appl Surf Sci 329 390-124
[10]  
Wang Y(2002)Surface plasmon resonance hydrogen sensor using an optical fibre Meas Sci Technol 13 118-026115