Fluid responsiveness is about stroke volume, and not pulse pressure Yogi: the power of Doppler fluid management and cardiovascular monitoring

被引:0
作者
Rob Phillips
Joe Brierley
机构
[1] The University of Queensland,The School of Medicine
[2] Uscom Limited,Director of Clinical Science
[3] Great Ormond St Hospital for Children and University College,PICU
来源
Journal of Clinical Monitoring and Computing | 2015年 / 29卷
关键词
Advanced haemodynamics; Doppler; Monitoring; Fluid responsiveness; Blood pressure; PPV;
D O I
暂无
中图分类号
学科分类号
摘要
Fluid infusion is one of the most common critical care interventions, yet approximately 50 % of all fluid interventions are unnecessary and potentially harmful. An improved approach to identification of fluid responsiveness is of clinical importance. Currently fluid responsiveness is most frequently identified by blood pressure (BP) measurements or a surrogate. However fluid responsiveness is simply the increase in stroke volume (SV) associated with volume expansion, and may not be reflected in BP or BP surrogates. Guyton demonstrated that BP = CO x SVR, and it is know that baroreceptor mediated autonomic nervous system regulation of SV and SVR to preserve BP may mask significant and critical changes in haemodynamics. Dr Pinsky in his recent J Clin Monit Comput Editorial evaluated the relative merits of pulse pressure variability (PPV) methods, a variant on BP measurement, for assessment of fluid responsiveness and promoted the use of physiologic challenges to augment the applicability of PPV. However this guidance is only half right. This letter reminds clinicians of the physiologic limitations of PPV as a measure of fluid responsiveness, even when combined with physiologic challenges, and recommends the replacement of BP with SV measurements. The combination of accurate Doppler measurement of SV and physiologic challenges, as Dr Pinsky recommends, is a physiologically rational and effective approach to identification of fluid responsiveness with established evidence. The direct monitoring of SV and SV changes has the potential to improve a long standing critical care and anaesthetic conundrum; when to give fluid and when to stop.
引用
收藏
页码:197 / 200
页数:3
相关论文
共 46 条
[1]  
Pinsky M(2014)It is amazing what you can see if you look J Clin Monit Comput 28 221-222
[2]  
Benes J(2014)Respiratory induced dynamic variations of stroke volume and its surrogates as predictors of fluid responsiveness: applicability in the early stages of specific critical states J Clin Monit Comput 28 225-231
[3]  
Zatloukal J(2013)Evaluation of pulse pressure variation validity criteria in critically ill patients; a prospective observational multicentre point-prevalence study Brit J Anes 39 666-688
[4]  
Kletecka J(2009)Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: an observational cohort study Crit Care 13 41-279
[5]  
Simanova A(2013)The increase of vasomotor tone avoids the ability of the dynamic preload indicators to estimate fluid responsiveness BMC Anesthesiol 27 273-768
[6]  
Haidingerova L(2013)Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac–Vigileo J Clin Monit Comput 14 R212-436
[7]  
Mahjoub Y(2010)Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters Crit Care 62 760-30
[8]  
Lejeune V(2007)An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery Anaesthesia 9 429-753
[9]  
Muller L(1990)Testing ultrasonic pulsed Doppler instruments with a physiologic string phantom J Ultrasound Med 10 25-undefined
[10]  
Thiel SW(1982)Evaluating Doppler devices using a moving string test target J Clin Ultrasound 100 748-undefined