Development and validation of a semi-automated and unsupervised method for femur segmentation from CT

被引:3
|
作者
Aldieri, Alessandra [1 ,2 ]
Biondi, Riccardo [3 ,4 ]
La Mattina, Antonino A. [2 ,5 ]
Szyszko, Julia A. [2 ,5 ]
Polizzi, Stefano [4 ]
Dall'Olio, Daniele [3 ]
Curti, Nico [3 ,6 ]
Castellani, Gastone [4 ]
Viceconti, Marco [2 ,5 ]
机构
[1] Politecn Torino, Dept Mech & Aerosp Engn, PolitoBIOMedLab, Turin, Italy
[2] IRCCS Ist Ortoped Rizzoli, Med Technol Lab, Bologna, Italy
[3] IRCCS Bologna Ist Sci Neurol Bologna, Bologna, Italy
[4] Alma Mater Studiorum Univ Bologna, Dept Med & Surg Sci, Bologna, Italy
[5] Alma Mater Studiorum Univ Bologna, Dept Ind Engn, Bologna, Italy
[6] Alma Mater Studiorum Univ Bologna, Dept Phys & Astron, Bologna, Italy
基金
欧盟地平线“2020”;
关键词
Bone and joint enhancement filter; CT; Femur segmentation; Finite element model; Graph-cut; Semi-automated segmentation; FRACTURES; BURDEN;
D O I
10.1038/s41598-024-57618-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Quantitative computed tomography (QCT)-based in silico models have demonstrated improved accuracy in predicting hip fractures with respect to the current gold standard, the areal bone mineral density. These models require that the femur bone is segmented as a first step. This task can be challenging, and in fact, it is often almost fully manual, which is time-consuming, operator-dependent, and hard to reproduce. This work proposes a semi-automated procedure for femur bone segmentation from CT images. The proposed procedure is based on the bone and joint enhancement filter and graph-cut algorithms. The semi-automated procedure performances were assessed on 10 subjects through comparison with the standard manual segmentation. Metrics based on the femur geometries and the risk of fracture assessed in silico resulting from the two segmentation procedures were considered. The average Hausdorff distance (0.03 +/- 0.01 mm) and the difference union ratio (0.06 +/- 0.02) metrics computed between the manual and semi-automated segmentations were significantly higher than those computed within the manual segmentations (0.01 +/- 0.01 mm and 0.03 +/- 0.02). Besides, a blind qualitative evaluation revealed that the semi-automated procedure was significantly superior (p < 0.001) to the manual one in terms of fidelity to the CT. As for the hip fracture risk assessed in silico starting from both segmentations, no significant difference emerged between the two (R-2 = 0.99). The proposed semi-automated segmentation procedure overcomes the manual one, shortening the segmentation time and providing a better segmentation. The method could be employed within CT-based in silico methodologies and to segment large volumes of images to train and test fully automated and supervised segmentation methods.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] An unsupervised semi-automated pulmonary nodule segmentation method based on enhanced region growing
    Ren, He
    Zhou, Lingxiao
    Liu, Gang
    Peng, Xueqing
    Shi, Weiya
    Xu, Huilin
    Shan, Fei
    Liu, Lei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (01) : 233 - +
  • [2] Development of a Semi-Automated Combined PET and CT Lung Lesion Segmentation Framework
    Rossi, Farli
    Mokri, Siti Salasiah
    Abd Rahni, Ashrani Aizzuddin
    MEDICAL IMAGING 2017: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2017, 10137
  • [3] Validation of a semi-automated segmentation algorithm with partial volume redistribution
    Glass, JO
    Reddick, WE
    Steen, RG
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 226 - 235
  • [4] A Semi-Automated Technique for Vertebrae Detection and Segmentation from CT Images of Spine
    Patrick, Jenny
    Indu, M. G.
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON COMMUNICATION SYSTEMS AND NETWORKS (COMNET), 2016, : 44 - 49
  • [5] IMPROVED SEMI-AUTOMATED SEGMENTATION OF CARDIAC CT AND MR IMAGES
    Li, Chao
    Jia, Xiao
    Sun, Ying
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 25 - 32
  • [6] Semi-automated Enhanced Breast Tumor Segmentation for CT Image
    Wang, Chao
    Li, Meng
    Liu, Xia
    Liu, Zaiyi
    Zang, Yali
    Liu, Zhenyu
    Dong, Di
    Chang, Changhong
    Tian, Jie
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 648 - 651
  • [7] SEMI-AUTOMATED LIVER CT SEGMENTATION USING LAPLACIAN MESHES
    Chartrand, G.
    Cresson, T.
    Chav, R.
    Gotra, A.
    Tang, A.
    DeGuise, I.
    2014 IEEE 11TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2014, : 641 - 644
  • [8] White matter hyperintensities segmentation: a new semi-automated method
    Iorio, Mariangela
    Spalletta, Gianfranco
    Chiapponi, Chiara
    Luccichenti, Giacomo
    Cacciari, Claudia
    Orfei, Maria D.
    Caltagirone, Carlo
    Piras, Fabrizio
    FRONTIERS IN AGING NEUROSCIENCE, 2013, 5
  • [9] Semi-automated CT Image Segmentation Provides Accurate LBM Measurements
    Devriese, J.
    Beels, L.
    Maes, A.
    Van de Wiele, C.
    Pottel, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S516 - S516
  • [10] Boundary Correction in Semi-Automated Segmentation Using Scribbling Method
    Rosidi, Rasyiqah Annani Mohd
    Khaizi, Aida Syafiqah Ahmad
    Gan, Hong-Seng
    Basarudin, Hafiz
    2017 INTERNATIONAL CONFERENCE ON ENGINEERING TECHNOLOGY AND TECHNOPRENEURSHIP (ICE2T), 2017,