Genetic algorithm based multi-resolution approach for de-speckling OCT image

被引:0
作者
Sima Sahu
Amit Kumar Singh
机构
[1] Malla Reddy Engineering College (Autonomous),Department of Electronics and Communication Engineering
[2] National Institute of Technology Patna,Department of Computer Science and Engineering
来源
Multimedia Tools and Applications | 2024年 / 83卷
关键词
Optical Coherence Tomography (OCT); Genetic Algorithm (GA); Wavelet transform; Optimization;
D O I
暂无
中图分类号
学科分类号
摘要
Reduction of noise has a considerable effect in medical image processing and computer vision analysis. Medical images are affected by noise due to low radiation exposure, physiological sources and electronic hardware noise. This affects diagnosis quality and quantitative measurements. In this paper, optical coherence tomography images are de-noised through wavelet transform, and the wavelet threshold value is further optimised using genetic algorithm (GA). The optimal levels of wavelet decomposition and threshold correction are performed through GA. The efficacy of the proposed method is verified by comparing the results with other reported wavelet- and GA-based methods in terms of Peak-Signal-to-Noise Ratio (PSNR) parameters. The quality of the resulting image is measured through structural similarity index measure (SSIM), correlation of coefficient (COC) and edge preservation index (EPI) parameters. The improvement of the proposed approach in terms of performance parameters PSNR, COC, SSIM and EPI is respectively 2.24%, 7.9%, 17.18% and 6.32% more than the existing GA-based method considering retinal OCT image. The results indicate that the suggested algorithm effectively suppresses the speckle noise of different noise variances, and the de-noised medical image is more suitable for clinical diagnosis.
引用
收藏
页码:31081 / 31102
页数:21
相关论文
共 119 条
[1]  
Achim A(2001)Novel Bayesian multiscale method for speckle removal in medical ultrasound images IEEE Trans Med Imaging 20 772-783
[2]  
Bezerianos A(2003)Speckle reduction in optical coherence tomography by frequency compounding J Biomed Opt 8 565-569
[3]  
Tsakalides P(2003)Speckle reduction in optical coherence tomography by path length encoded angular compounding J Biomed Opt 8 260-263
[4]  
Pircher M(2016)Adaptive noise-reducing anisotropic diffusion filter Neural Comput Appl 27 1273-1300
[5]  
Go E(2016)Enhancement and bias removal of optical coherence tomography images: an iterative approach with adaptive bilateral filtering Comput Biol Med 71 97-107
[6]  
Leitgeb R(2022)MRI de-noising using improved unbiased NLM filter J Ambient Intell Humanized Comput 14 1-12
[7]  
Fercher AF(2017)Speckle noise reduction in optical coherence tomography using two-dimensional curvelet-based dictionary learning J Med Signals Sens 7 86-361
[8]  
Hitzenberger CK(2017)Speckle noise reduction for optical coherence tomography images via non-local weighted group low-rank representation Laser Phys Lett 14 346-2645
[9]  
Iftimia N(2021)Optical coherence tomographic image denoising based on Chi-square similarity and fuzzy logic Opt Laser Technol 143 2630-1327
[10]  
Bouma BE(2015)Application of improved homogeneity similarity-based denoising in optical coherence tomography retinal images J Digit Imaging 28 1318-8352