High-resolution continuum source graphite furnace molecular absorption spectrometry compared with ion chromatography for quantitative determination of dissolved fluoride in river water samples

被引:0
作者
Philip Ley
Manfred Sturm
Thomas A. Ternes
Björn Meermann
机构
[1] Federal Institute of Hydrology,Department G2—Aquatic Chemistry
来源
Analytical and Bioanalytical Chemistry | 2017年 / 409卷
关键词
High-resolution continuum source graphite furnace molecular absorption spectrometry; Dissolved fluoride quantification; River water samples; Surface waters; Ion chromatography;
D O I
暂无
中图分类号
学科分类号
摘要
In addition to beneficial health effects, fluoride can also have adverse effects on humans, animals, and plants if the daily intake is strongly elevated. One main source of fluoride uptake is water, and thus several ordinances exist in Germany that declare permissible concentrations of fluoride in, for example, drinking water, mineral water, and landfill seepage water. Controlling the fluoride concentrations in aqueous matrices necessitate valid and fast analytical methods. In this work an alternative method for the determination of fluoride in surface waters based on high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) was applied. Fluoride detection was made possible by the formation of a diatomic molecule, GaF, and detection of characteristic molecular absorption. On HR-CS-GFMAS parameter optimization, the method was adapted to surface water sample analysis. The influence of potential main matrix constituents such as Na+, Ca2+, Mg2+, and Cl- as well as surface water sampling/storage conditions on the molecular absorption signal of GaF was investigated. Method validation demonstrated a low limit of detection (8.1 μg L-1) and a low limit of quantification (26.9 μg L-1), both sufficient for direct river water sample analysis after 0.45-μm filtration. The optimized HR-CS-GFMAS method was applied for the analysis of real water samples from the rivers Rhine and Moselle. For method validation, samples were also analyzed by an ion chromatography (IC) method. IC and HR-CS-GFMAS results both agreed well. In comparison with IC, HR-CS-GFMAS has higher sample throughput, a lower limit of detection and a lower limit of quantification, and higher selectivity, and is a very suitable method for the analysis of dissolved fluoride in river water.
引用
收藏
页码:6949 / 6958
页数:9
相关论文
共 73 条
  • [1] Edmunds WM(1996)Groundwater geochemistry and health: an overview Environ Geochem Health. 113 91-105
  • [2] Smedley PL(1993)Effects of fluoride emissions from industry on the fluoride concentration of soils and vegetation Biochem Syst Ecol. 21 195-208
  • [3] Haidouti C(2012)Method development for the determination of fluorine in water samples via the molecular absorption of strontium monofluoride formed in an electrothermal atomizer Spectrochim Acta Part B. 69 32-37
  • [4] Chronopoulou A(2013)Molecular absorption spectrometry in flames and furnaces: a review Anal Chim Acta. 804 1-15
  • [5] Chronopoulos J(2014)Determination of fluorine in milk and water via molecular absorption of barium monofluoride by high-resolution continuum source atomic absorption spectrometer Microchem J. 117 111-115
  • [6] Ozbek N(2011)Al determination in whole blood samples as AlF via high-resolution continuum source graphite furnace molecular absorption spectrometry: potential application to forensic diagnosis of drowning J Anal At Spectrom. 26 1964-1973
  • [7] Akman S(2011)Determination of fluorine in tea using high-resolution molecular absorption spectrometry with electrothermal vaporization of the calcium mono-fluoride CaF Talanta. 85 2681-2685
  • [8] Butcher DJ(2013)Molecule formation mechanisms of strontium mono fluoride in high-resolution continuum source electrothermal atomic absorption spectrometry Anal Sci. 29 741-746
  • [9] Ozbek N(2012)Fluorine speciation analysis using reverse phase liquid chromatography coupled off-line to continuum source molecular absorption spectrometry (CS-MAS): identification and quantification of novel fluorinated organic compounds in environmental and biological samples Anal Chem. 84 6213-6219
  • [10] Akman S(2006)Determination of non-metals via molecular absorption using high-resolution continuum source absorption spectrometry and graphite furnace atomization J Anal At Spectrom. 21 1314-1320