Heartbeat detector from ECG and PPG signals based on wavelet transform and upper envelopes

被引:0
作者
Manuel Merino-Monge
Juan Antonio Castro-García
Clara Lebrato-Vázquez
Isabel María Gómez-González
Alberto Jesús Molina-Cantero
机构
[1] E.T.S.I. Ingeniería Informática,Departamento de Tecnología Electrónica
[2] Universidad de Sevilla,undefined
来源
Physical and Engineering Sciences in Medicine | 2023年 / 46卷
关键词
ECG; PPG; Wavelet transform; Envelopes; Heartbeat detection;
D O I
暂无
中图分类号
学科分类号
摘要
The analysis of cardiac activity is one of the most common elements for evaluating the state of a subject, either to control possible health risks, sports performance, stress levels, etc. This activity can be recorded using different techniques, with electrocardiogram and photoplethysmogram being the most common. Both techniques make significantly different waveforms, however the first derivative of the photoplethysmographic data produces a signal structurally similar to the electrocardiogram, so any technique focusing on detecting QRS complexes, and thus heartbeats in electrocardiogram, is potentially applicable to photoplethysmogram. In this paper, we develop a technique based on the wavelet transform and envelopes to detect heartbeats in both electrocardiogram and photoplethysmogram. The wavelet transform is used to enhance QRS complexes with respect to other signal elements, while the envelopes are used as an adaptive threshold to determine their temporal location. We compared our approach with three other techniques using electrocardiogram signals from the Physionet database and photoplethysmographic signals from the DEAP database. Our proposal showed better performances when compared to others. When the electrocardiographic signal was considered, the method had an accuracy greater than 99.94%, a true positive rate of 99.96%, and positive prediction value of 99.76%. When photoplethysmographic signals were investigated, an accuracy greater than 99.27%, a true positive rate of 99.98% and positive prediction value of 99.50% were obtained. These results indicate that our proposal can be adapted better to the recording technology.
引用
收藏
页码:597 / 608
页数:11
相关论文
共 225 条
[91]  
Zhang Y(undefined)undefined undefined undefined undefined-undefined
[92]  
Zhang M(undefined)undefined undefined undefined undefined-undefined
[93]  
Liu W(undefined)undefined undefined undefined undefined-undefined
[94]  
Chang S(undefined)undefined undefined undefined undefined-undefined
[95]  
Wang H(undefined)undefined undefined undefined undefined-undefined
[96]  
He J(undefined)undefined undefined undefined undefined-undefined
[97]  
Huang Q(undefined)undefined undefined undefined undefined-undefined
[98]  
Avishek Paul SP(undefined)undefined undefined undefined undefined-undefined
[99]  
Nantu Das Mitra M(undefined)undefined undefined undefined undefined-undefined
[100]  
Xu W(undefined)undefined undefined undefined undefined-undefined