Three-dimensional on-chip continuous-flow polymerase chain reaction employing a single heater

被引:0
作者
Wenming Wu
Nae Yoon Lee
机构
[1] Kyungwon University,Division of BioNano Technology and College of BioNano Technology
[2] Korea Research Institute of Bioscience and Biotechnology (KRIBB),BioNanotechnology Research Center
来源
Analytical and Bioanalytical Chemistry | 2011年 / 400卷
关键词
On-chip polymerase chain reaction (PCR); Multi-layer microdevice; 3D fluidic conduit; A single heater; DNA amplification;
D O I
暂无
中图分类号
学科分类号
摘要
Multi-step temperature control in a polymerase chain reaction (PCR) is a limiting factor in device miniaturization and portability. In this study, we propose the fabrication of a three-dimensional (3D) microdevice employing a single heater to minimize temperature control required for an on-chip continuous-flow PCR as well as the overall footprint by stacking the device in multi-layers. Two poly(dimethylsiloxane) (PDMS) layers with differing thicknesses are vertically stacked with their microchannel-engraved sides facing down. Through-holes are made in the thicker PDMS layer, which is sandwiched between a glass substrate at the bottom and the thinner PDMS layer at the top. In this way, a fluidic conduit is realized in a 3D configuration. The assembled 3D microdevice is then placed onto a heater glass-side down. The interface of the two PDMS layers displays a relatively lower temperature than that of the PDMS and glass layers due to the low thermal conductivity of the PDMS and its physical distance from the heater. The denaturation temperature can be controlled by adjusting the temperature of the heater, while the annealing/extension temperature can be controlled automatically by molding the thicker bottom PDMS layer into the appropriate thickness calculated using a numerical derivation proposed in this study. In this way, a cumbersome temperature measurement step is eliminated. DNA amplification was successfully carried out using the proposed 3D fluidic microdevice, and the intensity of the resulting amplicon was comparable to that obtained using a thermal cycler. This novel concept of adopting a single heating source greatly simplifies the temperature control issue present in an on-chip continuous-flow PCR. It also allows the use of a commercialized hot plate as a potential heat source, paving the way for device miniaturization and portability in a highly cost-effective manner. In this study, a simple and facile technique to make arrays of through-holes for the fluidic interconnection inside a 3D channel configuration is also addressed.
引用
收藏
页码:2053 / 2060
页数:7
相关论文
共 150 条
[1]  
Burns MA(1998)undefined Science 282 484-487
[2]  
Johnson BN(2004)undefined Lab Chip 4 534-546
[3]  
Brahmasandra SN(2008)undefined Lab Chip 8 919-924
[4]  
Handique K(2009)undefined Biomed Microdevices 11 685-692
[5]  
Webster JR(1998)undefined Science 280 1046-1048
[6]  
Krishnan M(2003)undefined Anal Chem 75 6029-6033
[7]  
Sammarco TS(2008)undefined Sens Actuators B 130 836-841
[8]  
Man PM(2002)undefined Sens Actuators B 82 75-81
[9]  
Jones D(2003)undefined Anal Chem 75 288-295
[10]  
Heldsinger D(2009)undefined Anal Chem 81 302-306