A Robust N-Terminal Pro-Brain Natriuretic Peptide Assay for Clinical Diagnosis of Heart Failure in Elderly Patients

被引:0
作者
Xue Gong
Jiangling Wu
Jiajia Zhang
Zhongwei Jiang
Yi Wang
Pu Zhang
机构
[1] Chongqing Normal University,Engineering Research Center for Biotechnology of Active Substances (Ministry of Education), Chongqing Key Laboratory of Green Synthesis and Applications, College of Chemistry
[2] Chongqing Medical University,Chongqing Research Center for Pharmaceutical Engineering, College of Pharmacy
[3] University Town Hospital of Chongqing Medical University,Department of Clinical Laboratory
来源
Journal of Analysis and Testing | 2024年 / 8卷
关键词
NT-proBNP; Graphene oxide; Aptamer; Heart failure; Clinical diagnosis;
D O I
暂无
中图分类号
学科分类号
摘要
Heart failure (HF) is a clinical hallmark of cardiovascular syndrome leading to substantial morbidity, repeated hospitalization, and enormous healthcare expenditure. As elderly populations continue to increase, biomarker-guided diagnosis and treatment for age-related cardiac decline have become essential. Accumulating evidence demonstrates that N-terminal proBNP (NT-proBNP) can provide a unique window into the diagnosis and risk stratification with HF. Herein, a simple yet robust aptasensor is developed for on-site recognizing the NT-proBNP by its targeting aptamer, thus achieving the accurate diagnosis of HF. This aptasensing system is prepared by absorbing the fluorophore-labeled aptamer strand onto the graphene oxide (GO), leading to efficient quenching without possible off-site signal leakage. The aptamer strand can specifically identify target NT-proBNP molecules via a versatile conformational transformation, resulting in the desorption of the aptamer-NT-proBNP complexes from GO and re-generation fluorescence signal, thus allowing sensitive detection of NT-proBNP in 37 clinical blood samples. Taking advantage of the high specificity of aptamer-guaranteed recognitions of NT-proBNP, this aptasensor system readily achieves better diagnostic performance for HF than commercially adopted chemiluminescence immunoassay (Siemens, CLIA) in hospitals in terms of accuracy (89.2% vs 83.8%), specificity (89.5% vs 84.2%), and positive predictive value (88.9% vs 83.3%). This work provides a stable option for the diagnosis and treatment of elderly HF-related diseases in clinics.
引用
收藏
页码:74 / 82
页数:8
相关论文
共 271 条
  • [41] Li SL(undefined)undefined undefined undefined undefined-undefined
  • [42] Lin HL(undefined)undefined undefined undefined undefined-undefined
  • [43] Li WD(undefined)undefined undefined undefined undefined-undefined
  • [44] Zhu XZ(undefined)undefined undefined undefined undefined-undefined
  • [45] Zhang HL(undefined)undefined undefined undefined undefined-undefined
  • [46] Lewis LK(undefined)undefined undefined undefined undefined-undefined
  • [47] Raudsepp SD(undefined)undefined undefined undefined undefined-undefined
  • [48] Yandle TG(undefined)undefined undefined undefined undefined-undefined
  • [49] Prickett TC(undefined)undefined undefined undefined undefined-undefined
  • [50] Richards AM(undefined)undefined undefined undefined undefined-undefined