Ultrasensitive Detection of Cu2+ Using a Microcantilever Sensor Modified with L-Cysteine Self-Assembled Monolayer

被引:0
作者
Xiaohe Xu
Na Zhang
Gilbert M. Brown
Thomas G. Thundat
Hai-Feng Ji
机构
[1] Drexel University,Department of Chemistry
[2] Oak Ridge National Laboratory,Chemical Sciences Division
[3] University of Alberta,Department of Chemical and Materials Engineering
来源
Applied Biochemistry and Biotechnology | 2017年 / 183卷
关键词
Microcantilevers; Cu; detection; Adsorption-induced stress; Self-assembled monolayers (SAM); Chemically modified surfaces; And L-cysteine;
D O I
暂无
中图分类号
学科分类号
摘要
A microcantilever was modified with a self-assembled monolayer (SAM) of L-cysteine for the sensitively and selectively response to Cu(II) ions in aqueous solution. The microcantilever undergoes bending due to sorption of Cu(II) ions. The interaction of Cu(II) ions with the L-cysteine on the cantilever is diffusion controlled and does not follow a simple Langmuir adsorption model. A concentration of 10−10 M Cu(II) was detected in a fluid cell using this technology. Other cations, such as Ni2+, Zn2+, Pb2+, Cd2+, Ca2+, K+, and Na+, did not respond with a significant deflection, indicating that this L-cysteine-modified cantilever responded selectively and sensitively to Cu(II).
引用
收藏
页码:555 / 565
页数:10
相关论文
共 123 条
[1]  
Harris ED(2001)Copper homeostasis: the role of cellular transporters Nutrition Reviews 59 281-285
[2]  
Watts DL(1998)The nutritional relationships of copper Journal of Orthomolecular Medicine 4 99-109
[3]  
Turnlund JR(2004)Long-term high copper intake: effects on indexes of copper status, antioxidant status, and immune function in young men American Journal of Clinical Nutrition 79 1037-1044
[4]  
Jacob RA(1996)Vapor detection using resonating microcantilevers Analytical Chemistry 67 519-521
[5]  
Keen CL(1995)Adsorption-induced surface stress and its effects on resonance frequency of microcantilever Journal of Applied Physics 77 3618-3622
[6]  
Strain JJ(2012)A rapid and facile signal enhancement method for microcantilever-based immunoassays using the agglomeration of ferromagnetic nanoparticles Chemical Communications 48 7182-7184
[7]  
Kelley DS(2004)Cantilever-based biosensors Analytical and Bioanalytical Chemistry 379 946-959
[8]  
Domek JM(2012)Biosensing applications using dynamic-mode cantilever sensors: a review Biosensors & Bioelectronics 32 1-18
[9]  
Thundat T(2004)Cantilever transducers as a platform for chemical and biological sensors The Review of Scientific Instruments 75 2229-2253
[10]  
Chen GY(2010)Approaches to increasing surface stress for improving signal-to-noise ratio of microcantilever sensors Analytical Chemistry 82 1634-1642