Experimental performance investigation of a shell and tube heat exchanger by exergy based sensitivity analysis

被引:0
作者
Suha Orçun Mert
Alper Reis
机构
[1] Yuzuncu Yıl University,Department of Chemical Engineering
来源
Heat and Mass Transfer | 2016年 / 52卷
关键词
Heat Exchanger; Thermal System; Exergy Analysis; Exergy Efficiency; Shell Side;
D O I
暂无
中图分类号
学科分类号
摘要
Heat exchangers are used extensively in many industrial branches, primarily so in chemical and energy sectors. They also have important household usage as they are used in central and local heating systems. Any betterment on heat exchangers will serve greatly in preserving our already dwindling and costly energy resources. Strong approach of exergy analysis -which helps find out where the first steps should be taken in determining sources of inefficiencies and how to remedy them- will be used as a means to this end. The maximum useful work that can be harnessed from systems relationships with its environment is defined as exergy. In this study, the inlet and outlet flow rate values of fluids and temperature of hot stream both on shell and tube parts of a shell-tube heat exchange system have been inspected and their effects on the exergy efficiency of this thermal system have been analyzed. It is seen that the combination of high tube side inlet temperature, low shell side flow rate and high tube side flow rate are found to be the optimum for this experimental system with reaching 75, 65, and 32 % efficiencies respectively. Selecting operating conditions suitable to this behavior will help to increase the overall efficiency of shell-tube heat exchange systems and cause an increment in energy conservation.
引用
收藏
页码:1117 / 1123
页数:6
相关论文
共 57 条
[1]  
Dincer I(2002)The role of exergy in energy policy making Energy Policy 30 137-149
[2]  
Rosen MA(1999)Second-law analysis: approaches and implications Int J Energy Res 23 415-429
[3]  
Kanoglu M(2009)Exergy for better environment and sustainability Environ Dev Sustain 11 971-988
[4]  
Dincer I(1997)On exergy and environmental impact Int J Energy Res 21 643-654
[5]  
Cengel YA(2004)Cumulative exergy analysis of heat exchanger production and heat exchange processes Energy Fuels 18 1194-1198
[6]  
Rosen M(2009)Comprehensive exergy analysis of a ground-source heat pump system for both building heating and cooling modes Appl Energy 86 2560-2565
[7]  
Dincer I(2007)Exergy transfer effectiveness on heat exchanger for finite pressure drop Energy 32 2110-2120
[8]  
Feng X(2009)An experimental investigation of heat transfer enhancement for a shell-and-tube heat exchanger Appl Therm Eng 29 2433-2438
[9]  
Zhong G(2008)ANN modeling of compact heat exchangers Int J Energy Res 32 581-594
[10]  
Zhu P(2010)Multi-objective optimization of shell and tube heat exchangers Appl Therm Eng 30 1937-1945