Parametric Study on Effect of Adding Stiffener to Post-tensioned Steel Connection

被引:0
作者
M. R. Shiravand
A. Torabipour
S. Mahboubi
机构
[1] Shahid Beheshti University,Department of Civil Engineering
[2] Qazvin Azad University,Department of Civil Engineering
来源
International Journal of Steel Structures | 2019年 / 19卷
关键词
Post-tensioned connection; Self-centering moment-resisting frame; Stiffeners; Energy dissipation; Ductility;
D O I
暂无
中图分类号
学科分类号
摘要
Beam-to-column connections with post-tensioned (PT) elements are used in steel moment-resisting frames to provide adequate stiffness, strength, and ductility and to eliminate residual displacements under seismic loads. A steel PT connection has recently been developed with top and seat angles. In this connection, angles are used to dissipate energy under cyclic loading. This paper aims to investigate the influence of adding stiffeners to the top and seat angles on the cyclic responses of PT connections. To this end, a parametric study is performed to compare the effectiveness of stiffeners and some design parameters in the cyclic behavior of the PT connections. The design parameters are the angle thickness, the distance between the bolt line passing through the column and the heel of the angle (g2), the PT force of the strands, and number of strands. First, the results of finite element analyses are compared to previously conducted experiments on PT connections with top and seat angles through a verification study. In this way, finite element models of 23 PT connections are developed and analyzed under cyclic loading. Results indicate that adding the stiffeners to the angles, enhances the energy dissipation capacity, moment capacity, stiffness and ductility of the PT connection much higher than improving other design parameters.
引用
收藏
页码:478 / 494
页数:16
相关论文
共 38 条
[1]  
Annan CD(2013)Characterization of slip resistance of high strength bolted connections with zinc-based metallized faying surfaces Engineering Structures 56 2187-2196
[2]  
Chiza A(2005)Experimental studies on full-scale post-tensioned steel connections Journal of Structural Engineering ASCE 131 438-448
[3]  
Garlock M(2007)Behavior and design of post-tensioned steel frame systems Journal of Structural Engineering 133 389-399
[4]  
Ricles J(2011)Reliability-based evaluation of design and performance of steel self-centering moment frames Journal of Constructional Steel Research 67 1495-1505
[5]  
Sause R(2015)Finite element simulation of post tensioned steel connections with bolted angles under cyclic loading Journal of Structural Engineering ASCE 142 04015075-2121
[6]  
Garlock M (2017)Lateral load–drift response and limit states of post-tensioned steel beam–column connections: parametric study Journal of Structural Engineering ASCE 143 04017044-859
[7]  
Sause R(2001)Post-tensioned seismic resistant connections for steel frames Journal of Structural Engineering ASCE 127 2113-192
[8]  
Ricles JM(2002)Experimental evaluation of earthquake resistant post-tensioned steel connections Journal of Structural Engineering ASCE 128 850-16
[9]  
Herning G(2016)Behavior of post-tensioned connections with stiffened angles under cyclic loading Journal of Constructional Steel Research 116 183-1042
[10]  
Garlock M(2013)Finite element models and cyclic behavior of self-centering steel post-tensioned connections with web hourglass pins Engineering Structures 52 1-488