A Comprehensive Investigation of the Impact of NiO on the Radiation Attenuation Characteristics of (CaO-Li2O-NiO-SiO2) Glass Structure

被引:0
作者
Hani H. Negm
Asmaa A. Sdeek
Ahmed A. Ebrahim
机构
[1] Assiut University,Department of Physics, Faculty of Science
[2] Jouf University,Department of Physics, College of Science
来源
Journal of Electronic Materials | 2024年 / 53卷
关键词
Mass attenuation coefficient; silicate glass; stopping power; shielding materials; GEANT4;
D O I
暂无
中图分类号
学科分类号
摘要
In the present investigation, we examined the efficacy of lithium calcium silicate glasses doped with nickel for various radiation shielding applications. Specifically, we estimated the mass attenuation coefficients (μm) for samples with the composition (11.5–x)CaO-23.5Li2O-(x)NiO-65SiO2 (x = 0, 2.87, 5.75, 8.63, 11.5 mol.%) using Monte Carlo simulation (GEANT4), Phy-X/PSD, and XCOM programs over an energy range of 0.015–15 MeV. The results demonstrate a strong correlation between the extracted μm magnitudes from the simulation and calculation results. Next, we estimated various other parameters, including the linear attenuation coefficients (μ), half-value layer (HVL), tenth-value layer (TVL), mean free path (MFP), effective atomic number (Zeff), fast neutron removal cross sections (ΣR), relative dose distribution (RDD) for gamma rays, energy absorption buildup factors (EABF), and exposure buildup factors (EBF). We also assessed the alpha and beta shielding characteristics of the glass samples by estimating the continuous slowing down approximation range (CSDA) and total stopping power (TSP) magnitudes. Our findings indicate that μm, μ, Zeff, and ΣR magnitudes increased as the ratio of NiO in the samples increased. In contrast, we observed that HVL, TVL, RDD, MFP, EABF, and EBF magnitudes decreased as the NiO ratio increased. A higher percentage of NiO in the samples resulted in the supply of beta and alpha particles with shorter ranges. Overall, we conclude that the lithium calcium silicate glass doped with nickel with an 11.5% NiO percentage is the optimal specimen for obtaining superior photon and charged particle shielding benefits.
引用
收藏
页码:945 / 958
页数:13
相关论文
共 326 条
  • [11] Oriya A(2008)Usefulness of non-lead aprons in radiation protection for physicians performing interventional procedures Radiat. Prot. Dosimetry 6 577-undefined
  • [12] Takahashi K(2006)Evaluation of non–lead-based protective radiological material in spinal surgery Spine J. 498 372-undefined
  • [13] Inanami O(2018)The role of Ni2+ ions on structural and spectroscopic properties of Li J. Non Cryst. Solids 498 372-undefined
  • [14] Miura T(2018)O-ZrO J. Non Cryst. Solids 33 10596-undefined
  • [15] Abe Y(2022)-Y J. Mater. Sci. Mater. Electron. 551 123937-undefined
  • [16] Kuwabara M(2021)O J. Non Cryst. Solids 258 109281-undefined
  • [17] Kashiwakura I(2021)-SiO Chem. Phys. 180 119882-undefined
  • [18] Smirnova OA(2020) glass system Radiat. Phys. Chem. 532 169-undefined
  • [19] Kamran SC(2020)The role of Ni2+ ions on structural and spectroscopic properties of Li J. Non Cryst. Solids 70 110942-undefined
  • [20] Berrington de Gonzalez A(1981)O–ZrO Phys. Rep. 114 24858-undefined