Characterization of Impulse Radio Intrabody Communication System for Wireless Body Area Networks

被引:0
作者
Zibo Cai
MirHojjat Seyedi
Weiwei Zhang
Francois Rivet
Daniel T. H. Lai
机构
[1] Victoria University,College of Engineering and Science
[2] Nanchang Hang Kong University,Jiangxi Engineering Laboratory for Optoelectronics Testing Technology
[3] University of Bordeaux,IMS Laboratory
来源
Journal of Medical and Biological Engineering | 2017年 / 37卷
关键词
Field-programmable gate array (FPGA); Impulse radio (IR); Intrabody communication (IBC); Pulse position modulation (PPM); Transmitter design; Wireless body area network (WBAN);
D O I
暂无
中图分类号
学科分类号
摘要
Intrabody communication (IBC) is a promising data communication technique for body area networks. This short-distance communication approach uses human body tissue as the medium of signal propagation. IBC is defined as one of the physical layers for the new IEEE 802.15.6 or wireless body area network (WBAN) standard, which can provide a suitable data rate for real-time physiological data communication while consuming lower power compared to that of radio-frequency protocols such as Bluetooth. In this paper, impulse radio (IR) IBC (IR-IBC) is examined using a field-programmable gate array (FPGA) implementation of an IBC system. A carrier-free pulse position modulation (PPM) scheme is implemented using an IBC transmitter in an FPGA board. PPM is a modulation technique that uses time-based pulse characteristics to encode data based on IR concepts. The transmission performance of the scheme was evaluated through signal propagation measurements of the human arm using 4- and 8-PPM transmitters, respectively. 4 or 8 is the number of symbols during modulations. It was found that the received signal-to-noise ratio (SNR) decreases approximately 8.0 dB for a range of arm distances (5–50 cm) between the transmitter and receiver electrodes with constant noise power and various signal amplitudes. The SNR for the 4-PPM scheme is approximately 2 dB higher than that for the 8-PPM one. In addition, the bit error rate (BER) is theoretically analyzed for the human body channel with additive white Gaussian noise. The 4- and 8-PPM IBC systems have average BER values of 10−5 and 10−10, respectively. The results indicate the superiority of the 8-PPM scheme compared to the 4-PPM one when implementing the IBC system. The performance evaluation of the proposed IBC system will improve further IBC transceiver design.
引用
收藏
页码:74 / 84
页数:10
相关论文
共 43 条
  • [1] Kim J(2012)A dynamic duty cycle MAC algorithm for wireless body area networks International Journal of Bio-Science and Bio-Technology 4 83-92
  • [2] Song I(2013)Propagation models for body area networks: a survey and new outlook IEEE Antennas and Propagation Magazine 55 97-117
  • [3] Choi EJS(2014)Wireless body area networks: A survey IEEE Communications Surveys & Tutorials 16 1-29
  • [4] Smith D(1995)Personal area networks (PAN): near-field intra-body communication IBM Systems Journal 35 609-617
  • [5] Dino M(2015)The effects of electrode configuration on body channel communication based on analysis of vertical and horizontal electric dipoles IEEE Transactions on Microwave Theory and Techniques 63 1409-1420
  • [6] Tharaka L(2013)Experimental evaluation of implant UWB-IR transmission with living animal for body area networks IEEE Transactions on Microwave Theory and Techniques 61 183-192
  • [7] Leif H(2014)Effect of limb joints and limb movement on intrabody communications for body area network applications Journal of Medical and Biological Engineering (JMBE) 34 276-283
  • [8] Movassaghi S(2013)A survey on intrabody communications for body area network applications IEEE Transactions on Biomedical Engineering 60 2067-2077
  • [9] Mehran A(1998)Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz) Health Physics 74 494-522
  • [10] Justin L(2010)An empirical channel model for Human Body Communication Advanced Technologies for Communications (ATC) 352 20-22