Measurement of cardiovascular function using a novel view-sharing PET reconstruction method and tracer kinetic analysis

被引:0
作者
Paul R. Territo
Amanda A. Riley
Brian P. McCarthy
Gary D. Hutchins
机构
[1] Indiana University School of Medicine,Department of Radiology and Imaging Sciences
来源
EJNMMI Physics | / 3卷
关键词
Cardiac output; PET; View-sharing; Kinetic modeling;
D O I
暂无
中图分类号
学科分类号
摘要
Recent advancements in PET instrumentation have made the non-invasive assessment of cardiovascular function in small animals a reality. The majority of small animal PET systems use stationary detector gantries, thus affording high temporal resolution imaging of cardiac function. Systems designed to maximize spatial resolution and detection sensitivity employing rotating gantry designs are suboptimal when high temporal resolution imaging is needed. To overcome this limitation, the current work developed a novel view-sharing data analysis scheme suitable for dynamic cardiac PET imaging using 18F-NaF as the tracer and tracer kinetic model analysis. This scheme was tested in a rat model of cardiovascular function where the relationship between direct transonic flow measures of cardiac output were highly correlated (f(x) = 1.0216x − 24.233, R = 0.9158, p < 0.001) with the new model. Similarly, derived measures of stroke volume were also highly correlated (f(x) = 0.9655x − 0.0428, R = 0.9453, p < 0.001) with the current approach. Administration of xylazine caused a statistically significant increase in stroke volume (0.32 ± 0.07 ml, p = 0.003, n = 4) and a significant decrease in both heart rate (−155 ± 7.1 beats/min, p < 0.001, n = 4) and cardiac output (−75.9 ± 23.0 ml/kg min, p = 0.01, n = 4). These findings suggest that the new sinogram binning and kinetic modeling methods produce reliable cardiac function measures suitable for longitudinal monitoring of cardiovascular function.
引用
收藏
相关论文
共 87 条
[1]  
Walsh GM(1976)Direct Fick application for measurement of cardiac output in rat J Appl Physiol 40 849-53
[2]  
Tsuchiya M(1996)Validation of transonic small animal flowmeter for measurement of cardiac output and regional blood flow in the rat J Cardiovasc Pharmacol 27 482-6
[3]  
Frohlich ED(1978)The Stewart-Hamilton equations and the indicator dilution method SIAM J Appl Math 34 666-75
[4]  
Wen C(1993)Validity of thermal dilution technique for measurement of cardiac output in rats Am J Phys 265 H1007-13
[5]  
Li M(2004)Quantitative myocardial perfusion and coronary reserve in rats with 13 N-ammonia and small animal PET: impact of anesthesia and pharmacologic stress agents J Nucl Med 45 1924-30
[6]  
Whitworth JA(2003)Quantitative gated PET for the assessment of left ventricular function in small animals Journal of nuclear medicine : official publication, Society of Nuclear Medicine 44 1655-61
[7]  
Profant M(2004)Evaluation of the quantitative capability of a high-resolution positron emission tomography scanner for small animal imaging J Comput Assist Tomogr 28 842-8
[8]  
Vyska K(2003)Positron-emission tomography reporter gene expression imaging in rat myocardium Circulation 107 326-32
[9]  
Eckhardt U(2005)Noninvasive imaging of ex vivo intracoronarily delivered nonviral therapeutic transgene expression in heart Mol Ther 12 49-57
[10]  
Kissling G(2002)Positron emission tomography imaging of cardiac reporter gene expression in living rats Circulation 106 180-3