A Critical Comparison of Comparators Used to Demonstrate Credibility of Physics-Based Numerical Spine Models

被引:0
|
作者
Brittany Stott
Payman Afshari
Jeff Bischoff
Julien Clin
Alexandra Francois-Saint-Cyr
Mark Goodin
Sven Herrmann
Xiangui Liu
Mark Driscoll
机构
[1] McGill University,Musculoskeletal Biomechanics Research Lab, Department of Mechanical Engineering
[2] Montreal General Hospital,Orthopaedic Research Laboratory, Research Institute MUHC
[3] Johnson and Johnson,DePuy Synthes Spine
[4] Zimmer Biomet,undefined
[5] Corporate Research,undefined
[6] Numalogics,undefined
[7] Inc.,undefined
[8] Siemens Digital Industries Software,undefined
[9] SimuTech Group,undefined
[10] Inc.,undefined
[11] CADFEM Medical GmbH,undefined
[12] Stryker Orthopaedics,undefined
来源
Annals of Biomedical Engineering | 2023年 / 51卷
关键词
Verification; Validation; Uncertainty quantification; Model credibility; Regulatory affairs; Simulation; Virtual patient;
D O I
暂无
中图分类号
学科分类号
摘要
The ability of new medical devices and technology to demonstrate safety and effectiveness, and consequently acquire regulatory approval, has been dependent on benchtop, in vitro, and in vivo evidence and experimentation. Regulatory agencies have recently begun accepting computational models and simulations as credible evidence for virtual clinical trials and medical device development. However, it is crucial that any computational model undergo rigorous verification and validation activities to attain credibility for its context of use before it can be accepted for regulatory submission. Several recently published numerical models of the human spine were considered for their implementation of various comparators as a means of model validation. The comparators used in each published model were examined and classified as either an engineering or natural comparator. Further, a method of scoring the comparators was developed based on guidelines from ASME V&V40 and the draft guidance from the US FDA, and used to evaluate the pertinence of each comparator in model validation. Thus, this review article aimed to score the various comparators used to validate numerical models of the spine in order to examine the comparator’s ability to lend credibility towards computational models of the spine for specific contexts of use.
引用
收藏
页码:150 / 162
页数:12
相关论文
共 50 条
  • [1] A Critical Comparison of Comparators Used to Demonstrate Credibility of Physics-Based Numerical Spine Models
    Stott, Brittany
    Afshari, Payman
    Bischoff, Jeff
    Clin, Julien
    Francois-Saint-Cyr, Alexandra
    Goodin, Mark
    Herrmann, Sven
    Liu, Xiangui
    Driscoll, Mark
    ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (01) : 150 - 162
  • [2] Functionality and Safety Weaknesses in Integration of Physics-Based Models on Critical Embedded Systems
    Goettlich, Philipp
    Reuss, Hans-Christian
    2019 IEEE 30TH INTERNATIONAL SYMPOSIUM ON SOFTWARE RELIABILITY ENGINEERING WORKSHOPS (ISSREW 2019), 2019, : 67 - 72
  • [3] A comparison between physics-based Li-ion battery models
    Ali, Haider Adel Ali
    Raijmakers, Luc H. J.
    Chayambuka, Kudakwashe
    Danilov, Dmitri L.
    Notten, Peter H. L.
    Eichel, Rudiger-A.
    ELECTROCHIMICA ACTA, 2024, 493
  • [4] Model Selection Among Physics-Based Models
    Hombal, V. K.
    Mahadevan, S.
    JOURNAL OF MECHANICAL DESIGN, 2013, 135 (02)
  • [5] Inverse Problems for Physics-Based Process Models
    Bingham, Derek
    Butler, Troy
    Estep, Don
    ANNUAL REVIEW OF STATISTICS AND ITS APPLICATION, 2024, 11 : 461 - 482
  • [6] Physics-Based Hazard Assessment for Critical Structures Near Large Earthquake Sources
    Hutchings, L.
    Mert, A.
    Fahjan, Y.
    Novikova, T.
    Golara, A.
    Miah, M.
    Fergany, E.
    Foxall, W.
    BEST PRACTICES IN PHYSICS-BASED FAULT RUPTURE MODELS FOR SEISMIC HAZARD ASSESSMENT OF NUCLEAR INSTALLATIONS, 2018, : 311 - 338
  • [7] Reconciling the understanding of 'hydrophobicity' with physics-based models of proteins
    Harris, Robert C.
    Pettitt, B. Montgomery
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2016, 28 (08)
  • [8] Physics-Based Hazard Assessment for Critical Structures Near Large Earthquake Sources
    Hutchings, L.
    Mert, A.
    Fahjan, Y.
    Novikova, T.
    Golara, A.
    Miah, M.
    Fergany, E.
    Foxall, W.
    PURE AND APPLIED GEOPHYSICS, 2017, 174 (09) : 3635 - 3662
  • [9] Physics-Based Models for Catheter, Guidewire and Stent Simulation
    Lenoir, Julien
    Cotin, Stephane
    Duriez, Christian
    Neumann, Paul
    MEDICINE MEETS VIRTUAL REALITY 14: ACCELERATING CHANGE IN HEALTHCARE: NEXT MEDICAL TOOLKIT, 2006, 119 : 305 - +
  • [10] AlGaN/GaN HFET Models and the Prospects for Physics-Based Compact Models
    Trew, R. J.
    2010 IEEE COMPOUND SEMICONDUCTOR INTEGRATED CIRCUIT SYMPOSIUM (CSICS), 2010,