Precision of fit: zirconia three-unit fixed dental prostheses

被引:0
作者
Florian Beuer
Michael Naumann
Wolfgang Gernet
John A. Sorensen
机构
[1] Ludwig-Maximilians University,Department of Prosthodontics
[2] University of Leipzig,Department of Prosthodontics and Material Sciences
[3] Pacific Dental Institute,undefined
来源
Clinical Oral Investigations | 2009年 / 13卷
关键词
Zirconia; CAD/CAM; Fit; FDP; All-ceramic;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this in vitro study was to compare the precision of fit of substructures milled from semi-sintered zirconia blocks fabricated with two different computer-assisted design (CAD)/computer-assisted manufacturing (CAM) systems. Three-unit posterior fixed dental prostheses (FDP) were fabricated for standardized dies (n = 10) with the Lava CAD/CAM system (Lava) and the Procera-bridge-zirconia CAD/CAM system (Procera). After cementation to the dies, the FDP were embedded and sectioned. Four cross-sections were made of each abutment tooth, and marginal and internal fit were evaluated under an optical microscope. A one-way analysis of variance was used to compare data (α = 0.05). Mean gap dimensions at the marginal opening for Lava and Procera were 15 (±7) μm and 9 (±5) μm, respectively. Mean marginal openings (P = 0.012) and internal adaptation at two out of three measurement locations were significantly different. Within the limitations of this study, the results suggest that the accuracy of both investigated systems is satisfactory for clinical use.
引用
收藏
相关论文
共 144 条
[1]  
Andersson B(2001)Alumina ceramic implant abutments used for single-tooth replacement: a prospective 1- to 3-year multicenter study Int J Prosthodont 14 432-438
[2]  
Taylor A(1985)Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study J Prosthet Dent 53 24-29
[3]  
Lang BR(2008)Digital dentistry: an overview of recent developments for CAD/CAM generated restorations Br Dent J 204 505-511
[4]  
Scheller H(2004)Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2–5 years Eur J Oral Sci 112 197-204
[5]  
Scharer P(2005)Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations J Oral Rehabil 32 441-447
[6]  
Sorensen JA(2007)Fit of all-ceramic posterior fixed partial denture frameworks in vitro Int J Periodontics Restorative Dent 27 567-575
[7]  
Belser UC(2004)Precision of a CAD/CAM technique for the production of zirconium dioxide copings Int J Prosthodont 17 577-580
[8]  
MacEntee MI(2005)Guidelines for success with zirconia ceramics: the changing standards Pract Proced Aesthet Dent 17 508-461
[9]  
Richter WA(2002)Retention of selected core materials to zirconia posts Oper Dent 27 455-133
[10]  
Beuer F(2006)Two-year clinical performance of cast gold vs ceramic partial crowns Clin Oral Investig 10 126-352