Posterior Descending Coronary Artery Flow Reserve Assessment by Doppler Echocardiography in Children with and without Congenital Heart Defect Comparison with Invasive Technique

被引:0
作者
M. Aoki
K. Harada
M. Tamura
M. Toyono
G. Takada
机构
[1] Akita University School of Medicine,Department of Pediatrics
来源
Pediatric Cardiology | 2004年 / 25卷
关键词
Transthoracic Doppler echocardiography; Congenital heart disease; Coronary flow reserve; Right coronary artery;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate whether transthoracic Doppler echocardiography can reliably measure coronary flow velocity and coronary flow velocity reserve (CFVR) in the posterior descending coronary artery (PD) in children, we examined 32 patients who had congenital heart disease (ventricular septal defect in 10, tetralogy of Fallot in 6, tricuspid atresia in 3, double-outlet right ventricle in 2, patent ductus arteriosus in 2, and aortic valve stenosis in 2) and 7 patients who had a history of Kawasaki disease without stenosis or aneurysm formation of the coronary artery. Average peak flow velocity (APV) in the PD was measured by transthoracic Doppler echocardiography at the time of intracoronary Doppler study. CFVR was defined as the ratio of hyperemic to basal APV. Clear envelopes of basal and hyperemic APV in the PD were obtained in 23 of 32 patients by transthoracic Doppler echocardiography. APV obtained from transthoracic Doppler echocardiography correlated highly with that from the Doppler guidewire method (r = 0.91). The mean difference between transthoracic Doppler echocardiography and the Doppler guidewire method was 0.1 ± 2.9. There was an excellent correlation between transthoracic Doppler echocardiography and the Doppler guidewire method for the measurements of CFVR (r = 0.84). The mean difference between transthoracic Doppler echocardiography and Doppler guidewire was −0.016 ± 0.198. Noninvasive measurement of coronary flow velocity and CFVR in the PD using transthoracic Doppler echocardiography accurately reflects invasive measurement of coronary flow velocity and CFVR by the Doppler guidewire method in pediatric patients with various heart diseases.
引用
收藏
页码:647 / 653
页数:6
相关论文
共 97 条
[11]  
Shulkin BL(2003)Effects of balloon valvuloplasty on left anterior descending coronary artery blood flow in a neonate with critical aortic stenosis with transthoracic Doppler echocardiography J Am Soc Echocardiogr 16 88-90
[12]  
Hamaoka K(2002)Coronary flow reserve assessment by Doppler echocardiography in children with and without congenital heart defect: comparison with invasive technique J Am Soc Echocardiogr 15 1121-1126
[13]  
Onouchi Z(2001)Myocardial blood flow and flow reserve after coronary reimplantation in patients after arterial switch and Ross operation Circulation 103 1875-1880
[14]  
Kamiya Y(1994)Physiologic significance of chronic coronary aneurysms in patients with Kawasaki disease J Am Coll Cardiol 24 1633-1638
[15]  
Sakata K(2000)Long term consequences of regressed coronary aneurysms after Kawasaki disease: vascular wall morphology and function Heart 83 3071-311
[16]  
Hamaoka K(2000)Main coronary artery and coronary ostial stenosis in children: detection by transthoracic color flow and pulsed Doppler echocardiography J Am Soc Echocardiogr 13 255-263
[17]  
Onouchi Z(1998)Transthoracic Doppler echocardiography of normally originating coronary arteries in children J Am Soc Echocardiogr 11 409-420
[18]  
Ohmochi Y(2000)Aberrant origin of the left coronary artery from the right aortic sinus: surgical intervention based on echocardiographic diagnosis J Am Soc Echocardiogr 13 1117-1120
[19]  
Harada K(2002)Noninvasive assessment of coronary flow reserve in children with Kawasaki disease Heart 87 559-565
[20]  
Orino T(2002)Normal coronary flow reserve after arterial switch operation for transposition of the great arteries An intracoronary Doppler guidewire study. Circulation 106 1696-1702