Application of high-resolution mass spectrometry to measure low abundance isotope enrichment in individual muscle proteins

被引:0
作者
Kelly M. Hines
G. Charles Ford
Katherine A. Klaus
Brian A. Irving
Beverly L. Ford
Kenneth L. Johnson
Ian R. Lanza
K. Sreekumaran Nair
机构
[1] Mayo Clinic,Metabolomics Resource Core
[2] Mayo Clinic,Division of Endocrinology, Diabetes, Metabolism and Nutrition
[3] Mayo Clinic,Medical Genome Facility Proteomics Core
来源
Analytical and Bioanalytical Chemistry | 2015年 / 407卷
关键词
Stable isotope; Mass spectrometry; High resolution; Muscle protein; Protein synthesis; Fractional synthesis rate; LC-MS/MS;
D O I
暂无
中图分类号
学科分类号
摘要
Stable isotope-labeled amino acids have long been used to measure the fractional synthesis rate of proteins, although the mass spectrometry platforms used for such analyses have changed throughout the years. More recently, tandem mass spectrometers such as triple quadrupoles have been accepted as the standard platform for enrichment measurement due to their sensitivity and the enhanced specificity offered by multiple reaction monitoring (MRM) experiments. The limit in the utility of such platforms for enrichment analysis occurs when measuring very low levels of enrichment from small amounts of sample, particularly proteins isolated from two-dimensional gel electrophoresis (2D-GE), where interference from contaminant ions impacts the sensitivity of the measurement. We therefore applied a high-resolution orbitrap mass spectrometer to the analysis of [ring-13C6]-phenylalanine enrichment in individual muscle proteins isolated with 2D-GE. Comparison of samples analyzed on both platforms revealed that the high-resolution MS has significantly improved sensitivity relative to the triple quadrupole MS at very low-level enrichments due to its ability to resolve interferences in the m/z dimension. At higher enrichment levels, enrichment measurements from the orbitrap platform showed significant correlation (R2 > 0.5) with those of the triple quadrupole platform. Together, these results indicate that high-resolution MS platforms such as the orbitrap are not only as capable of performing isotope enrichment measurements as the more commonly preferred triple quadrupole instruments, but offer unparalleled advantages in terms of mass accuracy and sensitivity in the presence of similar-mass contaminants.
引用
收藏
页码:4045 / 4052
页数:7
相关论文
共 117 条
  • [1] Halliday D(1981)Skeletal muscle myosin heavy chain synthesis rate in healthy humans Proc Nutr Soc 40 321-334
  • [2] Read WW(1988)undefined Am J Physiol Endocrinol Metab 254 E208-E213
  • [3] Nair KS(1978)undefined Anal Chem 50 1465-1473
  • [4] Halliday D(1996)undefined J Invest Med 44 273A-490
  • [5] Griggs RC(1992)undefined Biol Mass Spec 21 486-523
  • [6] Matthews DE(1982)undefined Clin Sci 63 519-E307
  • [7] Hayes JM(1994)undefined Am J Physiol Endocrinol Metab 266 E298-S96
  • [8] Balagopal P(1997)undefined Muscle Nerve 5 S93-E800
  • [9] Ljungqvist O(1997)undefined Am J Physiol Endocrinol Metab 273 E790-E891
  • [10] Ford GC(2005)undefined Am J Physiol Endocrinol Metab 288 E883-2039