A pneumatic micropump incorporated with a normally closed valve capable of generating a high pumping rate and a high back pressure

被引:0
作者
Yi-Ning Yang
Suz-Kai Hsiung
Gwo-Bin Lee
机构
[1] National Cheng Kung University,Department of Engineering Science
[2] Industrial Technology Research Institute,Medical Electronics and Device Technology Center
来源
Microfluidics and Nanofluidics | 2009年 / 6卷
关键词
Microfluidics; MEMS; Micropump; Normally closed microvalve;
D O I
暂无
中图分类号
学科分类号
摘要
This study reports on a new pneumatic micropump integrated with a normally closed valve that is capable of generating a high pumping rate and a high back pressure. The micropump consists of a sample flow microchannel, three underlying pneumatic air chambers, resilient polydimethylsiloxane (PDMS) membrane structures and a normally closed valve. The normally closed valve of the micropump is a PDMS-based floating block structure located inside the sample flow microchannel, which is activated by hydraulic pressure created by the peristaltic motion of the PDMS membranes. The valve is used to effectively increase pumping rates and back pressures since it is utilized to prevent backflow. Experimental results indicate that a pumping rate as high as 900 μL/min at a driving frequency of 90 Hz and at an applied pressure of 20 psi (1.378 × 105 Nt/m2) can be obtained. The back pressure on the micropump can be as high as 85 cm-H2O (8,610.5 Nt/m2) at the same operation conditions. The micropump is fabricated by soft lithography processes and can be easily integrated with other microfluidic devices. To demonstrate its capability to prevent cross contamination during chemical analysis applications, two micropumps and a V-shape channel are integrated to perform a titration of two chemical solutions, specifically sodium hydroxide (NaOH) and benzoic acid (C6H5COOH). Experimental data show that mixing with a pH value ranging from 2.8 to 12.3 can be successfully titrated. The development of this micropump can be a promising approach for further biomedical and chemical analysis applications.
引用
收藏
页码:823 / 833
页数:10
相关论文
共 104 条
  • [21] Gu Y(2003)Microchip-based chemical and biochemical analysis systems J Chromatogr A 987 197-204
  • [22] Loftness PE(2003)A phase-change type micropump with aluminum flap valves J Micromech Microeng 13 286-294
  • [23] Siegel RA(2000)Monolithic microfabricated valves and pumps by multilayer soft lithography Science 288 113-116
  • [24] Ziaie B(1990)Thermopneumatic micropump based on microengineering techniques Sens Actuators A 21 198-202
  • [25] Bourouina T(2005)Automatic bio-sampling chips integrated with micropumps and microvalves for multiple disease detection Biosens Bioelectron 21 419-425
  • [26] Bosseboeuf A(2006)Pneumatically driven peristaltic micropumps utilizing serpentine-shape channels J Micromech Microeng 16 341-348
  • [27] Grandchamp J(2005)A ball valve micropump in glass fabricated by powder blasting Sens Actuators B 110 1-7
  • [28] Duffy DC(1996)Fabrication and testing of a pair of passive bivalvular microvalves composed of p + silicon diaphragms Sens Actuators A 57 75-78
  • [29] Schueller OJA(undefined)undefined undefined undefined undefined-undefined
  • [30] Brittain ST(undefined)undefined undefined undefined undefined-undefined