Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT

被引:0
作者
Seong-Jang Kim
In-Ju Kim
Yun-Seong Kim
Yong-Ki Kim
机构
[1] Pusan National University Hospital,Department of Nuclear Medicine
[2] Pusan National University Hospital,Department of Internal Medicine
来源
The International Journal of Cardiovascular Imaging | 2005年 / 21卷
关键词
end-diastolic volume; end-systolic volume; gated blood pool SPECT; 8 and 16 frame; left ventricular ejection fraction;
D O I
暂无
中图分类号
学科分类号
摘要
Gated blood pool SPECT (GBPS) is an alternative to planar radionuclide ventriculography (PRNV) and offers potential advantages. The aim of this study was to compare 8 and 16 frame GBPS for the determination of left ventricular ejection fraction(LVEF) and left ventricular volumes (LV) in subjects underwent two consecutive GBPS. Method: About 66 consecutive patients (30 men, 36 women; mean age 62.3 ± 10.4 years) referred for PRNV for evaluation of preoperative cardiac risk stratification (n=40), prechemotherapy cardiac function evaluation (n=18, breast cancer), and congestive heart failure patients (n=8). All patients underwent PRNV of 16 frame and GBPS with both of 8 and 16 frame. Results: The mean LVEF calculated with PRNV (58.3 ± 16.8), showed statistically lower than 8-GBPS (70.6 ± 17.7), and 16-GBPS (69.9 ± 16.8) (PRNV vs. 8-GBPS, p < 0.01; PRNV vs 16-GBPS, p < 0.01; 8-GBPS vs 16-GBPS, p > 0.05). The correlation of LVEFS between 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9194 (p < 0.01, 95% CI=0.8712–0.9500). The mean left ventricular end-diastolic volumes (EDV) calculated with 8-GBPS (83.2 ± 33.5 ml), and 16-GBPS (88.4 ± 36.8 ml) showed no statistical differences (p > 0.05). The mean left ventricular end-systolic volumes (ESV) calculated with 8-GBPS (28.1 ± 31.4 ml), and 16-GBPS (30.5 ± 33 ml) showed also no statistical differences (p > 0.05). Comparison of EDV from 8 and 16-GBPS yielded a correlation coefficient of 0.7430 (p < 0.01, 95% CI=0.6108-0.8349). The correlation between ESV of 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9522 (p < 0.01, 95% CI=0.9228–0.9705). Conclusion: This study demonstrated that the LVEFs of 8-GBPS correlated well with that of 16-GBPS. The LVEF of PRNV was significantly lower than those of 8 and 16-GBPS. Also, left ventricular EDV and ESV of 8-GBPS correlated well with those of 16-GBPS. Also, further studies, involving large lumber patients, should be performed to validate the usefulness of GBPS for the evaluation of left ventricular diastolic function.
引用
收藏
页码:261 / 266
页数:5
相关论文
共 50 条
  • [41] Comparison of gated blood pool SPECT and spiral multidetector computed tomography in the assessment of right ventricular functional parameters: validation with first-pass radionuclide angiography
    Jung S. Lee
    Jun S. Lee
    Seong-Jang Kim
    In-Ju Kim
    Yong-Ki Kim
    Ki S. Choo
    Annals of Nuclear Medicine, 2007, 21 : 159 - 166
  • [42] Impact of Wiener filter in determining the left ventricular volume and ejection fraction using thallium-201 gated SPECT
    Manrique, A
    Hitzel, A
    Gardin, I
    Dacher, JN
    Véra, P
    NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (08) : 907 - 914
  • [43] Comparison between Tc-99m-sestamibi gated myocardial perfusion SPECT and echocardiography in assessment of left ventricular volumes and ejection fraction - effect of perfusion defect and small heart
    Danesh-Sani, Seyed Hashem
    Zakavi, Seyed Rasoul
    Oskoueian, Leyla
    Kakhki, Vahid-Reza Dabbagh
    NUCLEAR MEDICINE REVIEW, 2014, 17 (02) : 70 - 74
  • [44] Results from an Australian and New Zealand audit of left ventricular ejection fraction from gated heart pool scan analysis
    Bailey, Elizabeth A.
    Bailey, Dale L.
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (01) : 102 - 111
  • [45] Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: Comparison of 4 software programs
    Nakajima, K
    Higuchi, T
    Taki, J
    Kawano, M
    Tonami, N
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (10) : 1571 - 1578
  • [46] Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts
    Hambye, AS
    Vervaet, A
    Dobbeleir, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (12) : 1606 - 1613
  • [47] Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts
    Anne-Sophie Hambye
    Ann Vervaet
    André Dobbeleir
    European Journal of Nuclear Medicine and Molecular Imaging, 2004, 31 : 1606 - 1613
  • [48] Effect of prone versus supine positioning on left ventricular ejection fraction (LVEF) and heart rate using ECG gated Tl-201 myocardial perfusion scans and gated cardiac blood pool scans
    Yap, Kenneth
    Campbell, Patrina
    Cherk, Martin
    McGrath, Catherine
    Kalff, Victor
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (05) : 525 - 531
  • [49] Evaluation of Left Ventricular Volumes and Ejection Fraction from Gated Myocardial Perfusion SPECT Processed with "Myovation Evolution": Comparison of Three Automated Software Packages using Cardiac Magnetic Resonance as Reference
    Calandri, Enrico
    Guana, Francesca
    Pultrone, Mirco
    Leuzzi, Stefano
    Chiorino, Giovanna
    Soligo, Eleonora
    Frantellizzi, Viviana
    Gallina, Sonya
    Liberatore, Mauro
    De Vincentis, Giuseppe
    CURRENT RADIOPHARMACEUTICALS, 2021, 14 (02) : 112 - 120
  • [50] Multiple-Gated Acquisition Scan With Normal Left Ventricular Ejection Fraction and LBBB
    Mannelli, Lorenzo
    Caldwell, James H.
    Elman, Shana
    Lewis, David H.
    Do, Bernard W.
    Vesselle, Hubert
    CLINICAL NUCLEAR MEDICINE, 2014, 39 (09) : E410 - E412