Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT

被引:0
|
作者
Seong-Jang Kim
In-Ju Kim
Yun-Seong Kim
Yong-Ki Kim
机构
[1] Pusan National University Hospital,Department of Nuclear Medicine
[2] Pusan National University Hospital,Department of Internal Medicine
来源
The International Journal of Cardiovascular Imaging | 2005年 / 21卷
关键词
end-diastolic volume; end-systolic volume; gated blood pool SPECT; 8 and 16 frame; left ventricular ejection fraction;
D O I
暂无
中图分类号
学科分类号
摘要
Gated blood pool SPECT (GBPS) is an alternative to planar radionuclide ventriculography (PRNV) and offers potential advantages. The aim of this study was to compare 8 and 16 frame GBPS for the determination of left ventricular ejection fraction(LVEF) and left ventricular volumes (LV) in subjects underwent two consecutive GBPS. Method: About 66 consecutive patients (30 men, 36 women; mean age 62.3 ± 10.4 years) referred for PRNV for evaluation of preoperative cardiac risk stratification (n=40), prechemotherapy cardiac function evaluation (n=18, breast cancer), and congestive heart failure patients (n=8). All patients underwent PRNV of 16 frame and GBPS with both of 8 and 16 frame. Results: The mean LVEF calculated with PRNV (58.3 ± 16.8), showed statistically lower than 8-GBPS (70.6 ± 17.7), and 16-GBPS (69.9 ± 16.8) (PRNV vs. 8-GBPS, p < 0.01; PRNV vs 16-GBPS, p < 0.01; 8-GBPS vs 16-GBPS, p > 0.05). The correlation of LVEFS between 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9194 (p < 0.01, 95% CI=0.8712–0.9500). The mean left ventricular end-diastolic volumes (EDV) calculated with 8-GBPS (83.2 ± 33.5 ml), and 16-GBPS (88.4 ± 36.8 ml) showed no statistical differences (p > 0.05). The mean left ventricular end-systolic volumes (ESV) calculated with 8-GBPS (28.1 ± 31.4 ml), and 16-GBPS (30.5 ± 33 ml) showed also no statistical differences (p > 0.05). Comparison of EDV from 8 and 16-GBPS yielded a correlation coefficient of 0.7430 (p < 0.01, 95% CI=0.6108-0.8349). The correlation between ESV of 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9522 (p < 0.01, 95% CI=0.9228–0.9705). Conclusion: This study demonstrated that the LVEFs of 8-GBPS correlated well with that of 16-GBPS. The LVEF of PRNV was significantly lower than those of 8 and 16-GBPS. Also, left ventricular EDV and ESV of 8-GBPS correlated well with those of 16-GBPS. Also, further studies, involving large lumber patients, should be performed to validate the usefulness of GBPS for the evaluation of left ventricular diastolic function.
引用
收藏
页码:261 / 266
页数:5
相关论文
共 50 条
  • [31] Gated blood pool SPECT: The estimation of right ventricular volume and function is algorithm dependent in a clinical setting
    Dercle, Laurent
    Ouali, Monia
    Pascal, Pierre
    Giraudmaillet, Thomas
    Chisin, Roland
    Lairez, Olivier
    Marachet, Marie-Agnes
    Rousseau, Herve
    Bastie, Delphine
    Ben Bouallegue, Faycal
    Berry, Isabelle
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (03) : 483 - 492
  • [32] Low-dose dobutamine stress gated blood pool SPECT assessment of left ventricular contractile reserve in ischemic cardiomyopathy: a feasibility study
    Vladimir V. Shipulin
    Sergey L. Andreev
    Andrew S. Pryakhin
    Andrew V. Mochula
    Alina N. Maltseva
    Svetlana I. Sazonova
    Vladimir M. Shipulin
    Samia Massalha
    Konstantin V. Zavadovsky
    European Journal of Nuclear Medicine and Molecular Imaging, 2022, 49 : 2219 - 2231
  • [33] Planar imaging versus gated blood-pool SPECT for the assessment of ventricular performance: A multicenter study
    Groch, MW
    DePuey, EG
    Belzberg, AC
    Erwin, WD
    Kamran, M
    Barnett, CA
    Hendel, RC
    Spies, SM
    Ali, A
    Marshall, RC
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (12) : 1773 - 1779
  • [34] Gated blood pool SPECT: The estimation of right ventricular volume and function is algorithm dependent in a clinical setting
    Laurent Dercle
    Monia Ouali
    Pierre Pascal
    Thomas Giraudmaillet
    Roland Chisin
    Olivier Lairez
    Marie-Agnès Marachet
    Hervé Rousseau
    Delphine Bastié
    Fayçal Ben Bouallègue
    Isabelle Berry
    Journal of Nuclear Cardiology, 2015, 22 : 483 - 492
  • [35] Low-dose dobutamine stress gated blood pool SPECT assessment of left ventricular contractile reserve in ischemic cardiomyopathy: a feasibility study
    Shipulin, Vladimir V.
    Andreev, Sergey L.
    Pryakhin, Andrew S.
    Mochula, Andrew, V
    Maltseva, Alina N.
    Sazonova, Svetlana, I
    Shipulin, Vladimir M.
    Massalha, Samia
    Zavadovsky, Konstantin, V
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (07) : 2219 - 2231
  • [36] Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT
    Lum, DP
    Coel, MN
    NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (03) : 259 - 266
  • [37] Assessment of global and regional left ventricular contractile function in patients with known or suspected coronary artery disease: Comparison between myocardial perfusion scintigraphy and gated blood pool SPECT data
    Halkovich, A.
    Mariano-Goulart, D.
    Bourdon, A.
    Sainmont, M.
    Benkiran, M.
    Ben Bouallegue, F.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2014, 38 (01): : 59 - 70
  • [38] Assessment of left ventricular ejection fraction with quantitative gated SPECT: Accuracy and correlation with first-pass radionuclide angiography
    Enrique Vallejo
    Donald P. Dione
    Albert J. Sinusas
    Frans J. Th. Wackers
    Journal of Nuclear Cardiology, 2000, 7 : 461 - 470
  • [39] Assessment of left ventricular ejection fraction with quantitative gated SPECT: Accuracy and correlation with first-pass radionuclide angiography
    Vallejo, E
    Dione, DP
    Sinusas, AJ
    Wackers, FJT
    JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (05) : 461 - 470
  • [40] Comparison of gated blood pool SPECT and spiral multidetector computed tomography in the assessment of right ventricular functional parameters: validation with first-pass radionuclide angiography
    Lee, Jung S.
    Lee, Jun S.
    Kim, Seong-Jang
    Kim, In-Ju
    Kim, Yong-Ki
    Choo, Ki S.
    ANNALS OF NUCLEAR MEDICINE, 2007, 21 (03) : 159 - 166