Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT

被引:0
|
作者
Seong-Jang Kim
In-Ju Kim
Yun-Seong Kim
Yong-Ki Kim
机构
[1] Pusan National University Hospital,Department of Nuclear Medicine
[2] Pusan National University Hospital,Department of Internal Medicine
来源
The International Journal of Cardiovascular Imaging | 2005年 / 21卷
关键词
end-diastolic volume; end-systolic volume; gated blood pool SPECT; 8 and 16 frame; left ventricular ejection fraction;
D O I
暂无
中图分类号
学科分类号
摘要
Gated blood pool SPECT (GBPS) is an alternative to planar radionuclide ventriculography (PRNV) and offers potential advantages. The aim of this study was to compare 8 and 16 frame GBPS for the determination of left ventricular ejection fraction(LVEF) and left ventricular volumes (LV) in subjects underwent two consecutive GBPS. Method: About 66 consecutive patients (30 men, 36 women; mean age 62.3 ± 10.4 years) referred for PRNV for evaluation of preoperative cardiac risk stratification (n=40), prechemotherapy cardiac function evaluation (n=18, breast cancer), and congestive heart failure patients (n=8). All patients underwent PRNV of 16 frame and GBPS with both of 8 and 16 frame. Results: The mean LVEF calculated with PRNV (58.3 ± 16.8), showed statistically lower than 8-GBPS (70.6 ± 17.7), and 16-GBPS (69.9 ± 16.8) (PRNV vs. 8-GBPS, p < 0.01; PRNV vs 16-GBPS, p < 0.01; 8-GBPS vs 16-GBPS, p > 0.05). The correlation of LVEFS between 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9194 (p < 0.01, 95% CI=0.8712–0.9500). The mean left ventricular end-diastolic volumes (EDV) calculated with 8-GBPS (83.2 ± 33.5 ml), and 16-GBPS (88.4 ± 36.8 ml) showed no statistical differences (p > 0.05). The mean left ventricular end-systolic volumes (ESV) calculated with 8-GBPS (28.1 ± 31.4 ml), and 16-GBPS (30.5 ± 33 ml) showed also no statistical differences (p > 0.05). Comparison of EDV from 8 and 16-GBPS yielded a correlation coefficient of 0.7430 (p < 0.01, 95% CI=0.6108-0.8349). The correlation between ESV of 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9522 (p < 0.01, 95% CI=0.9228–0.9705). Conclusion: This study demonstrated that the LVEFs of 8-GBPS correlated well with that of 16-GBPS. The LVEF of PRNV was significantly lower than those of 8 and 16-GBPS. Also, left ventricular EDV and ESV of 8-GBPS correlated well with those of 16-GBPS. Also, further studies, involving large lumber patients, should be performed to validate the usefulness of GBPS for the evaluation of left ventricular diastolic function.
引用
收藏
页码:261 / 266
页数:5
相关论文
共 50 条
  • [21] Comparison of totally automated and manual processing for calculation of left ventricular volumes and ejection fraction using gated myocardial perfusion SPECT
    Al-Shammari, Amirah Fahad
    Afzal, Uzma
    CARDIOMETRY, 2022, (22): : 136 - 142
  • [22] The value of a completely automatic ECG gated blood pool SPECT processing method for the estimation of global systolic left ventricular function
    Daou, D
    Coaguila, C
    Benada, A
    Razzouk, M
    Haidar, M
    Colin, P
    Lebtahi, R
    Slama, M
    Le Guludec, D
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (03) : 271 - 276
  • [23] Evaluation of new automated gated-SPECT and echocardiographic methods for calculating left ventricular volumes and ejection fraction
    Gjertsson, Peter
    Ekberg, Sofia
    Lomsky, Milan
    Gan, Li-Ming
    Edenbrandt, Lars
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 136 (02) : 171 - 177
  • [24] Reproducibility and accuracy of gated SPECT for determination of left ventricular volumes and ejection fraction: Experimental validation using MRI
    Vallejo, E
    Dione, DP
    Bruni, WL
    Constable, RT
    Borek, PP
    Soares, JP
    Carr, JG
    Condos, SG
    Wackers, FJT
    Sinusas, AJ
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 874 - 882
  • [25] Comparison of prone and supine determination of left ventricular ejection fraction measured by gated myocardial SPECT.
    Papathanassiou, D
    Liehn, JC
    Wampach, H
    Perault, C
    Ouzan, J
    Pron, T
    Dedienne, B
    Bouchard, A
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 1997, 21 (8-9): : 458 - 461
  • [26] COMPARISON OF LEFT VENTRICULAR VOLUMES AND EJECTION FRACTION ASSESSMENT BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY COMPARED WITH GATED MYOCARDIAL SPECT IN PATIENTS WITH ISCHEMIC CARDIOMYOPATHY
    Hutyra, Martin
    Skala, Tomas
    Kaminek, Milan
    Zapletalova, Jana
    BIOMEDICAL PAPERS-OLOMOUC, 2010, 154 (01): : 47 - 54
  • [27] A comparison and validation of blood-pool imaging and ECG-gated SPET myocardial perfusion imaging to assess left ventricular ejection fraction
    Xia, Wei
    Lv, Zhongwei
    Wang, Guoyu
    Cai, Haidong
    Ni, Jing
    Zhang, Yuna
    Ye, Beihong
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2010, 13 (03): : 241 - 245
  • [28] Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation of the exini heart software package
    Winz, Oliver H.
    Meyer, Philipp T.
    Knollmann, Daniela
    Lipke, Claudia S. A.
    Kuhl, Harald P.
    Oelve, Carola
    Schaefer, Wolfgang M.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2009, 29 (02) : 89 - 94
  • [29] Variability of serial same-day left ventricular ejection fraction using quantitative gated spect
    Enrique Vallejo
    Hugo Chaya
    Gerardo Plancarte
    Diana Victoria
    David Bialostozky
    Journal of Nuclear Cardiology, 2002, 9 : 377 - 384
  • [30] Variability of serial same-day left ventricular ejection fraction using quantitative gated SPECT
    Vallejo, E
    Chaya, H
    Plancarte, G
    Victoria, D
    Bialostozky, D
    JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (04) : 377 - 384