A self-assembled monolayer of protein G was fabricated to develop an immunosensor based on surface plasmon resonance (SPR), thereby improving the performance of the antibody-based biosensor through immobilizing the antibody molecules (IgG). As such, 11-mercaptoundecanoic acid (11-MUA) was adsorbed on a gold (Au) support, while the non-reactive hydrophilic surface was changed through substituting the carboxylic acid group (-COOH) in the 11-MUA molecule using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrocholide (EDAC). The formation of the self-assembled protein G layer on the Au substrate and binding of the antibody and antigen were investigated using SPR spectroscopy, while the surface topographies of the fabricated thin films were analyzed using atomic force microscopy (AFM). A fabricated monoclonal antibody (Mab) layer was applied for detectingE. coli O157∶H7. As a result, a linear relationship was achieved between the pathogen concentration and the SPR angle shift, plus the detection limit was enhanced up to 102 CFU/mL.
引用
收藏
页码:227 / 232
页数:5
相关论文
共 91 条
  • [1] Kricka L. J.(2001)Microchips, microarrays, biochips and nanochips: personal laboratories for the 21st century Clin. Chim. Acta 307 219-223
  • [2] Borrebaeck C. A. K.(2000)Antibodies in diagnostics-from immunoassays to protein chips Rev. Immunol. Today 21 379-382
  • [3] Kurdowska A.(2002)Monoclonal antibodies to rabbit a-2-macroglobulin and their use in a sensitive ELISA assay J. Immunol. Methods 270 147-153
  • [4] Miller E. J.(1999)Use of chicken egg-yolk antibodies against K88+fimbral antigen for quantitative analysis of enterotoxigenic J. Sci. Food Agric. 79 1513-1518
  • [5] Krupa A.(1997) (ETEC) K88 by a sandwich ELSIA Thin Solid Films 307 294-297
  • [6] Noble J. M.(2000)The study of the antigen-antibody reaction by fluorescence method in LB films for immunosensor Sens. Actuat. B 66 190-192
  • [7] Sakao Y.(1998)Study on highly sensitive potentiometric IgG immunosensor Biosens. Bioelectron. 13 1213-1225
  • [8] Kim J. W.(1999)Covalent coupling of immunoglobulin G to self-assembled monolayers as a method for immobilizing the interfacial recognition layer of a surface plasmon resonance immunosensor Science 284 948-951
  • [9] Jin L. Z.(2002)Design and self-assembly of open regular 3D mesostructure Colloids Surf. B 23 327-337
  • [10] Cho S. H.(2000)Adsorption behavior and photoelectric response characteristics of bacteriorhodpsin thin films fabricated by self-assembly technique Trends Analytical Chemistry 19 530-540