Experimental studies of thermal performance of an evacuated tube heat pipe solar collector in Polish climatic conditions

被引:0
作者
Alicja Siuta-Olcha
Tomasz Cholewa
Kinga Dopieralska-Howoruszko
机构
[1] Lublin University of Technology,Faculty of Environmental Engineering
来源
Environmental Science and Pollution Research | 2021年 / 28卷
关键词
Solar energy; Evacuated tube solar collector; Thermal efficiency; Exergy efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
This work presents the results of experimental studies on the energy performance of an evacuated solar collector, heat pipe type, consisting of 24 tubes, over the period of 2 months. The solar collector with a gross area of 3.9 m2 is part the solar hot water test system located in Lublin (Poland). The effect of the weather conditions and operating parameters on the thermal and exergy efficiencies of the evacuated tube solar collector has been defined. The solar irradiation per month for July amounted to 80 kWh/m2, and for August, it equalled 112.8 kWh/m2. The average thermal gain was found to be in July 163 W/m2 and in August 145 W/m2, respectively. For the considered study period, the average value of energy yield in the solar collector was obtained at the level of 4.28 MJ/(m2·d). The average monthly energy efficiencies of the solar collector in July and August were 45.3% and 32.9%, respectively, while the average monthly exergy efficiencies reached 2.62% and 2.15%, respectively. Increasing the wind speed to 0.86 m/s decreases the thermal efficiency and the exergy efficiency by 67% and 41%, respectively.
引用
收藏
页码:14319 / 14328
页数:9
相关论文
共 50 条
  • [41] Effects of Aluminum Fin Thickness Coated with a Solar Paint on the Thermal Performance of Evacuated Tube Collector
    Andemeskel, Amanuel
    Suriwong, Tawat
    Wamae, Warisa
    2017 INTERNATIONAL CONFERENCE ON ALTERNATIVE ENERGY IN DEVELOPING COUNTRIES AND EMERGING ECONOMIES, 2017, 138 : 429 - 434
  • [42] Novel method of thermal behavior prediction of evacuated tube solar collector
    Nokhosteen, Arman
    Sobhansarbandi, Sarvenaz
    SOLAR ENERGY, 2020, 204 : 761 - 768
  • [43] Comparative Studies on the Efficiency of Solar Flat-plate Collector and Evacuated Tube Collector
    Yan, Huilei
    Zhang, Hua
    Shao, Qiuping
    ADVANCES IN ENERGY SCIENCE AND TECHNOLOGY, PTS 1-4, 2013, 291-294 : 3 - 8
  • [44] Experimental investigation and performance evaluation of a vacuum tube solar air collector based on micro heat pipe arrays
    Zhu, Ting-ting
    Zhao, Yao-hua
    Diao, Yan-hua
    Li, Feng-fei
    Quan, Zhen-hua
    JOURNAL OF CLEANER PRODUCTION, 2017, 142 : 3517 - 3526
  • [45] Performance analysis of evacuated tube solar collector for residential heating in Mongolia
    Purevdalai, E.
    Amarbayar, A.
    Akisawa, Atsushi
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2015, 2015, : 1120 - 1126
  • [46] Thermal performance assessment by cerium oxide nano-enhanced coating on evacuated tube solar collector absorber tubes
    Sathish, T.
    RESULTS IN ENGINEERING, 2025, 25
  • [47] Effect of PCM material and vibration on the performance of evacuated tube solar collector
    Eidan, Adel A.
    Ali, Sarah H.
    Al Sahlani, Assaad
    Alshukri, Mohammed J.
    Ahmed, Ali Mahmood
    AL-bonsrulah, Hussein A. Z.
    Raja, Vijayanandh
    Al-Bahrani, Mohammed
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2022, 17 : 1261 - 1270
  • [48] ENERGY AND EXERGY EFFICIENCY OF HEAT PIPE EVACUATED TUBE SOLAR COLLECTORS
    Jafarkazemi, Farzad
    Ahmadifard, Emad
    Abdi, Hossein
    THERMAL SCIENCE, 2016, 20 (01): : 327 - 335
  • [49] Thermal power measurement of the novel evacuated tube solar collector and conventional solar collector during simultaneous operation
    Rybar, Radim
    Beer, Martin
    Cehlar, Michal
    MEASUREMENT, 2016, 88 : 153 - 164
  • [50] Exergoeconomic and exergoenvironmental analysis of the evacuated tube heat pipe; a experimental study
    Karabuga, Arif
    Yakut, Melik Ziya
    Utlu, Zafer
    INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2021, 24 (03) : 261 - 269