Dipolar and quadrupolar detection using an FT-ICR MS setup at the MPIK Heidelberg

被引:0
作者
Michael Heck
Klaus Blaum
R. Burcu Cakirli
Daniel Rodríguez
Lutz Schweikhard
Stefan Stahl
Marta Ubieto-Díaz
机构
[1] Max-Planck-Insitute for Nuclear Physics,Department of Physics
[2] University of Istanbul,Institute of Physics
[3] Universidad de Granada,undefined
[4] Ernst-Moritz-Arndt University Greifswald,undefined
[5] Stahl-Electronics,undefined
来源
Hyperfine Interactions | 2011年 / 199卷
关键词
Penning traps; FT-ICR MS; Detection methods; High resolution mass spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
Dipolar and single-phase two-electrode quadrupolar detection schemes have been investigated at a Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) setup built for the KATRIN experiment at the Max-Planck-Institute for Nuclear Physics (MPIK) in Heidelberg. We present first experimental results of 7Li +  signals from a cylindrical Penning trap configuration for both detection schemes. While the prominent signal of the conventional dipolar detection scheme marks the reduced cyclotron frequency, the main signal for the quadrupolar detection appears at the sum of the reduced cyclotron frequency and the magnetron frequency. For ideal trapping fields, this sum frequency equals the ion cyclotron frequency νc = qB/(2πm). Sidebands due to the combined motions of the cyclotron mode and magnetron mode are observed by quadrupolar detection which allows the determination of the respective combinations of eigenfrequencies.
引用
收藏
页码:347 / 355
页数:8
相关论文
共 57 条
[21]  
Comisarow MB(2009)Recent developments in ion detection techniques for Penning trap mass spectrometry at TRIGA-TRAP Nucl. Instrum. Methods A 606 474-undefined
[22]  
Marshall AG(2010)Position-sensitive ion detection in precision Penning trap mass spectrometry AIP Conf. Proc. 1265 483-undefined
[23]  
Hendrickson CL(2009)Broad-band FT-ICR MS for the Penning-trap mass spectrometer MATS Eur. J. Mass Spectrom. 15 283-undefined
[24]  
Jackson GS(1990)Unintended parametric ejection of ions from an ion cyclotron resonance trap by two-electrode axialization Int. J. Mass Spectrom. Ion Process. 98 25-undefined
[25]  
Dunbar RC(1989)Quadrupole-detection FT-ICR mass spectrometry Rev. Sci. Instrum. 60 2631-undefined
[26]  
Otten EW(1991)A new detection scheme for Fourier transform-ion cyclotron resonance spectrometry in Penning traps Int. J. Mass Spectrom. Ion Procees. 107 281-undefined
[27]  
Weinheimer C(1993)Theory of quadrupole detection Fourier transform ion cyclotron resonance J. Am. Soc. Mass Spectrom. 4 433-undefined
[28]  
Ubieto-Díaz M(undefined)Excitation modes for Fourier transform-ion cyclotron resonance mass spectrometry undefined undefined undefined-undefined
[29]  
Rodríguez D(undefined)undefined undefined undefined undefined-undefined
[30]  
Lukic S(undefined)undefined undefined undefined undefined-undefined