High dose rate brachytherapy source measurement intercomparison

被引:0
作者
Joel Poder
Ryan L. Smith
Nikki Shelton
May Whitaker
Duncan Butler
Annette Haworth
机构
[1] Chris O’Brien Lifehouse,Radiation Oncology
[2] University of Wollongong,Centre of Medical Radiation Physics
[3] The Alfred Hospital,Alfred Health Radiation Oncology
[4] RMIT University,School of Applied Sciences
[5] The Austin Hospital,Olivia Newton John Cancer and Wellness Centre
[6] Australian Radiation Protection and Nuclear Safety Agency,School of Physics
[7] Physical Sciences,undefined
[8] Peter MacCallum Cancer Centre,undefined
[9] University of Sydney,undefined
来源
Australasian Physical & Engineering Sciences in Medicine | 2017年 / 40卷
关键词
Brachytherapy; Well-chamber; Calibration; Intercomparison;
D O I
暂无
中图分类号
学科分类号
摘要
This work presents a comparison of air kerma rate (AKR) measurements performed by multiple radiotherapy centres for a single HDR 192Ir source. Two separate groups (consisting of 15 centres) performed AKR measurements at one of two host centres in Australia. Each group travelled to one of the host centres and measured the AKR of a single 192Ir source using their own equipment and local protocols. Results were compared to the 192Ir source calibration certificate provided by the manufacturer by means of a ratio of measured to certified AKR. The comparisons showed remarkably consistent results with the maximum deviation in measurement from the decay-corrected source certificate value being 1.1%. The maximum percentage difference between any two measurements was less than 2%. The comparisons demonstrated the consistency of well-chambers used for 192Ir AKR measurements in Australia, despite the lack of a local calibration service, and served as a valuable focal point for the exchange of ideas and dosimetry methods.
引用
收藏
页码:377 / 383
页数:6
相关论文
共 98 条
  • [1] Hoskin PJ(2012)Randomised trial of external beam radiotherapy alone or combined with high-dose-rate brachytherapy boost for localised prostate cancer Radiother Oncol 103 217-222
  • [2] Rojas AM(2011)Long-term outcomes of concomitant chemoradiotherapy incorporating high-dose-rate brachytherapy to treat locally advanced cervical cancer Tumori 98 615-621
  • [3] Bownes PJ(2009)Clinical impact of computed tomography-based image-guided brachytherapy for cervix cancer using the tandem-ring applicator—the Addenbrooke’s experience Clin Oncol 21 175-182
  • [4] Lowe GJ(2013)Australasian brachytherapy audit: results of the ‘end-to-end’ dosimetry pilot study J Med Imagin Radiat Oncol 57 490-498
  • [5] Ostler PJ(2010)The 2009 survey of therapy equipment and dosimetry practices in Australian radiotherapy centres Australas Phys Eng Sci Med 33 229-285
  • [6] Bryant L(2015)Quality assurance in MR image guided adaptive brachytherapy for cervical cancer: final results of the EMBRACE study dummy run Radiother Oncol 117 548-554
  • [7] Lee HJ(2013)ACPSEM brachytherapy working group recommendations for quality assurance in brachytherapy Australas Phys Eng Sci Med 36 387-276
  • [8] Kim YS(1992)A dosimetric intercomparison of megavoltage photon beams in UK radiotherapy centres Phys Med Biol 37 445-156
  • [9] Shin SS(2003)Bladder and rectum dose defined from MRI based treatment planning for cervix cancer brachytherapy: comparison of dose–volume histograms for organ contours and organ wall, comparison with ICRU rectum and bladder reference point Radiother Oncol 68 269-93
  • [10] Nam J-H(2005)A dosimetric intercomparison of brachytherapy facilities in Ireland, Scotland and the North of England Radiother Oncol 74 149-498