Corneal epithelial thickness measured by Fourier-domain optical coherence tomography; [Die korneale Epitheldicke und ihre Messung mittels Fourier Domain optischer Kohärenztomographie]

被引:0
|
作者
Wang T. [1 ]
Li F. [1 ]
Wang S. [1 ]
Shi W. [1 ]
机构
[1] Shandong Eye Hospital, Shandong Eye Institute, Shandong Academy of Medical Sciences, 5 Yanerdao Road, Qingdao
基金
中国国家自然科学基金;
关键词
Corneal Epithelial; Optical Coherence Tomography; Thickness;
D O I
10.1007/s00717-015-0267-4
中图分类号
学科分类号
摘要
Purpose: To characterize the corneal epithelial thickness profile with Fourier-domain optical coherence tomography (FD-OCT). Methods: Epithelial thickness measurements were obtained by FD-OCT within the central 6-mm zone of the cornea in all subjects who were divided into groups of A (0–20 years), B (21–40 years), C (41–60 years), and D (> 60 years) according to age. Profile maps of the central, average, minimum, maximum, standard deviation, every ring, and radiate area of corneal epithelial thickness were plotted. Differences of the epithelial thickness values at the central cornea and peripheral locations were calculated. Results: The mean epithelial thickness was 54.48 ± 3.11 μm at the central cornea, 53.53 ± 3.06 μm at the 2–5 mm annular area, and 52.45 ± 3.13 μm at the 5–6 mm annular area, with no statistically significant differences between left and right eyes and between both genders. From the center to the edge, the corneal epithelial thickness became thinner obviously for all groups (p = 0.000), and in the 5–6 mm zone, the epithelial thickness was inversely associated with age (p = 0.000). The average epithelial thickness map showed that the corneal epithelium was 1.54 μm thicker inferiorly than superiorly (p = 0.000). The thinnest part was on the superior temporal region (52.49 ± 3.48 μm, 50.78 ± 3.68 μm), while the thickest was on the inferior nasal (54.56 ± 3.44 μm, 53.68 ± 3.72 μm). Conclusions: Corneal epithelial thickness unevenly distributes, with the thinnest part on the superior temporal region and the thickest on the inferior nasal region. The 5–6 mm annular area corneal epithelium becomes thinned with aging, while the central corneal epithelial thickness has no obvious change. © 2015, Springer-Verlag Wien.
引用
收藏
页码:3 / 9
页数:6
相关论文
共 50 条
  • [31] Gouy phase shift in Fourier-domain optical coherence tomography - art. no. 684726
    Lamouche, G.
    Vergnole, S.
    Dufour, M. L.
    Gauthier, B.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XII, 2008, 6847 : 84726 - 84726
  • [32] Fourier-domain optical coherence tomography: optimization of signal-to-noise ratio in full space
    Zvyagin, AV
    OPTICS COMMUNICATIONS, 2004, 242 (1-3) : 97 - 108
  • [33] Single-shot parallel full range complex Fourier-domain optical coherence tomography
    Huang, Bingjie
    Bu, Peng
    Nan, Nan
    Wang, Xiangzhao
    9TH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE (PIBM 2010), 2011, 277
  • [34] Morphological evaluation of Schnyder's crystalline corneal dystrophy by laser scanning confocal microscopy and Fourier-domain optical coherence tomography
    Jing, Yang
    Wang, Liya
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 37 (03) : 308 - 312
  • [35] Corneal Power Measurement Obtained by Fourier-Domain Optical Coherence Tomography: Repeatability, Reproducibility, and Comparison With Scheimpflug and Automated Keratometry Measurements
    Wang, Qinmei
    Hua, Yanjun
    Savini, Giacomo
    Chen, Hao
    Bao, Fangjun
    Lin, Shishi
    Lu, Weicong
    Huang, Jinhai
    CORNEA, 2015, 34 (10) : 1266 - 1271
  • [36] In-focus line field Fourier-domain optical coherence tomography by complex numerical method
    Nakamura, Yoshifumi
    Sugisaka, Jun-ichiro
    Yasuno, Yoshiaki
    Sando, Yusuke
    Endo, Takashi
    Itoh, Masahide
    Yatagai, Toyohiko
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [37] Guiding glaucoma laser surgery using Fourier-domain optical coherence tomography at 1.3 μm
    Bayleyegn, Masreshaw D.
    Makhlouf, Houssine
    Crotti, Caroline
    Plamann, Karsten
    Dubois, Arnaud
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE III, 2012, 8427
  • [38] Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography
    Bruce, Alison
    Pacey, Ian E.
    Dharni, Poonam
    Scally, Andy J.
    Barrett, Brendan T.
    OPEN OPHTHALMOLOGY JOURNAL, 2009, 3 : 10 - 14
  • [39] High-sensitive full-range optical vibrometry based on Fourier-domain optical coherence tomography
    Subhash, Hrebesh M.
    Leahy, Martin
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [40] Optical module to extend any Fourier-domain optical coherence tomography system into a polarisation-sensitive system
    Rivet, Sylvain
    Marques, Manuel J.
    Bradu, Adrian
    Podoleanu, Adrian
    JOURNAL OF OPTICS, 2016, 18 (06)