Intra- and inter-rater reliability of ultrasound measures of the anterior cruciate ligament

被引:0
|
作者
Zachary A. Sievert
Hunter J. Bennett
Joshua T. Weinhandl
机构
[1] Old Dominion University,Department of Human Movement Sciences, 2016 Student Recreation Center
[2] The University of Tennessee,Department of Kinesiology, Recreation, and Sport Studies
来源
Journal of Ultrasound | 2021年 / 24卷
关键词
ACL; Ultrasound; Reliability; Anteromedial bundle;
D O I
暂无
中图分类号
学科分类号
摘要
Diagnostic ultrasound has accurately and reliably been utilized by clinicians to determine ACL morphology at the tibial insertion site, specifically measuring the entire ACL diameter, the anteromedial bundle (AM), and the posterolateral bundle. However, intra- and inter-rater reliability of these measures in a research setting is unknown. The purpose of this study was to determine intra- and inter-rater reliability of ultrasound measures of ACL diameter and AM diameter in researchers with low-to-moderate ultrasound experience. We hypothesized that intra- and inter-rater reliability of ACL and AM diameters would reach acceptable levels, a minimal intraclass correlation (ICC) of 0.6 and a desired ICC of 0.8 with an α of 0.05 and β of 0.20. Fourteen volunteers participated in this study. During the ACL ultrasound measures, participants were seated with their knee flexed to at least 90°. Each rater recorded two images of both the right and left ACL and AM bundles. Next, participants were re-examined by rater one for intra-rater reliability analyses. Two-way random ICCs were conducted for intra-rater (between sessions) and inter-rater reliability for both the full ACL and the AM bundle diameters. Standard errors between sessions for Rater 1’s AM bundle and ACL diameters were less than 0.03 cm. Intra-rater reliability was higher in AM bundles compared to full ACL, 0.76 versus 0.59, respectively. Standard errors between Rater 1 and Rater 2 were less than 0.03 cm. Inter-rater reliability was higher in AM bundles compared to full ACL, 0.71 versus 0.41, respectively. The results of the study indicate researchers with low-to-moderate training with ultrasound measures can locate and measure the ACL, but with greater reliability using the AM.
引用
收藏
页码:49 / 55
页数:6
相关论文
共 50 条
  • [1] Intra- and inter-rater reliability of ultrasound measures of the anterior cruciate ligament
    Sievert, Zachary A.
    Bennett, Hunter J.
    Weinhandl, Joshua T.
    JOURNAL OF ULTRASOUND, 2021, 24 (01) : 49 - 55
  • [2] A Procedure for Measuring Anterior Scalene Morphology and Quality with Ultrasound Imaging: An Intra- and Inter-rater Reliability Study
    Valera-Calero, Juan Antonio
    Gomez-Sanchez, Sonia
    Fernandez-de-las-Penas, Cesar
    Plaza-Manzano, Gustavo
    Sanchez-Jorge, Sandra
    Navarro-Santana, Marcos Jose
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (08): : 1817 - 1823
  • [3] Intra- and inter-rater reliability for analysis of hyoid displacement measured with sonography
    Macrae, Phoebe R.
    Doeltgen, Sebastian H.
    Jones, Richard D.
    Huckabee, Maggie-Lee
    JOURNAL OF CLINICAL ULTRASOUND, 2012, 40 (02) : 74 - 78
  • [4] Clinical evaluation of the anterior translation of glenohumeral joint using ultrasonography: an intra- and inter-rater reliability study
    Joseph, Leonard H.
    Hussain, Rizuana I.
    Pirunsan, Ubon
    Naicker, Amaramalar S.
    Htwe, Ohnmar
    Paungmali, Aatit
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (02) : 169 - 174
  • [5] Intra- and Inter-Rater Reliability of the Modified Tuck Jump Assessment
    Fort-Vanmeerhaeghe, Azahara
    Montalvo, Alicia M.
    Lloyd, Rhodri S.
    Read, Paul
    Myer, Gregory D.
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2017, 16 (01) : 117 - 124
  • [6] Intra- and inter-rater reliability in ultrasonographic measurements of coracohumeral distance
    Guerra-Rodriguez, Diego
    Guerrero-Henriquez, Juan
    Basilio, Daniel
    Mendez-Rebolledo, Guillermo
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2024, 69
  • [7] Intra- and Inter-Rater Reliability of Ultrasound Imaging to Measure Tensor Fasciae Latae Muscle Size
    Estebanez-de-Miguel, Elena
    Ceballos-Laita, Luis
    Gomez-Vallejo, Jesus
    Jimenez-del-Barrio, Sandra
    Malo-Urries, Miguel
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (05)
  • [8] M-Mode Ultrasound Examination of Soleus Muscle in Healthy Subjects: Intra- and Inter-Rater Reliability Study
    Romero-Morales, Carlos
    Calvo-Lobo, Cesar
    Navarro-Flores, Emmanuel
    Mazoteras-Pardo, Victoria
    Garcia-Bermejo, Paula
    Lopez-Lopez, Daniel
    Martinez-Jimenez, Eva Maria
    De-la-Cruz-Torres, Blanca
    HEALTHCARE, 2020, 8 (04)
  • [9] INTRA- AND INTER-RATER RELIABILITY OF THE SELECTIVE FUNCTIONAL MOVEMENT ASSESSMENT (SFMA)
    Glaws, Kathryn R.
    Juneau, Christopher M.
    Becker, Lindsay C.
    Di Stasi, Stephanie L.
    Hewett, Timothy E.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2014, 9 (02): : 195 - 207
  • [10] Inter-rater reliability of Rolimeter measurements between anterior cruciate ligament injured and normal contra lateral knees
    Papandreou, MG
    Antonogiannakis, E
    Karabalis, C
    Karliaftis, K
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (07) : 592 - 597